
1
Models Included:
• ALP3GT15A826
• ALP3GT32A826
• ALP3GT32A898
3. Connect the unit to electrical outlet with appropriate amperage rating (see serial tag on machine).
4. Once power has been supplied to the unit, flip the toggle switch to the ‘ON’ position (located on the rear of the unit), the water tank will
begin to fill. When the water level in the tank reaches the probe, the heating element(s) will turn on.
5. Water in the heating tank will require approximately a half hour before reaching operating temperature (factory setting of 202°F). When
the unit reaches operating temperature, it will display “READY TO BREW”.
BREWING INSTRUCTIONS
1. The brewer should be ON. Confirm this at the rear toggle switch, then press the ON/OFF button. Ready-to-Brew should be displayed.
2. Place an empty decanter on warmer plate.
3. Place a new paper filter into the brew cone.
6. Press the BREW button on the
control panel to start brewing.
5. Slide the filled brewcone into the
rails on the coffee brewer.
4. Pour the proper amount of ground
coffee into the brewcone.
W
ilbur
C
urtis
C
o
., i
nC
.
Service Manual – Alpha McDonald’s Fresh-Trac
Important Safeguards/Conventions
This appliance is designed for commercial use. Any servicing other than cleaning and preventive maintenance should be performed by an
authorized Wilbur Curtis service technician.
• Do NOT immerse the unit in water or any other liquid
• To reduce the risk of fire or electric shock, do NOT open service panels. No user serviceable parts inside.
• Keep hands and other items away from hot surfaces of unit during operation.
• Never clean with scouring powders, bleach or harsh chemicals.
Symbols
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
The Curtis Alpha G3 is Factory Pre-Set and Ready to Go… Right from the Box.
Following are the Factory Settings for the Alpha Fresh-Trac:
• Brew Temperature = 202°F
• Brew Volume = Set to vessel requirements (60 oz).
System Requirements:
• Water Source 20 – 90 PSI (minimum flow rate of 1 GPM)
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
SETUP STEPS
1. The unit should be level (left to right - front to back), on a secure surface.
2. Connect the water line to the water inlet fitting on the rear of the unit. Water volume flow to the machine should be consistent. Use
tubing sized sufficiently to provide a minimum flow rate of 1 gallon per minute.
NOTE: A water filtration system must be used to help maintain trouble-free operation.
Air must be purged from the cartridge prior to
connection to equipment.
In areas with extremely hard water, we highly recommend the use of a Curtis approved water filter. For our
full line of filters, please log on to www.wilburcurtis.com.
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) is required so that the unit can be moved
for cleaning.
2. This unit must be installed with adequate back flow protection to comply with applicable federal, state and local codes.
3. Water pipe connections and fixtures directly connected to a portable water supply shall be sized, installed and main
-
tained in accordance with federal, state, and local codes.
CAUTION:
DO NOT
connect the unit to
hot water supply.
The inlet valve is not rated for
hot water.
CAUTION:
Follow
this setup procedure
before attempting
to use this unit. Failure to
follow these instructions can
result in injury and/or void of
warranty.
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO., INC.
6913 West Acco Street
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800-421-6150
Fax: 323-837-2410
CAUTION:
Equipment must be
installed to comply
with applicable federal, state,
and local plumbing/electrical
codes.
Содержание ALP3GT15A826
Страница 6: ...6 ILLUSTRATED PARTS LIST ALPHA G3...
Страница 8: ...8 ELECTRICAL SCHEMATIC...