MEGA-FLOW CONE FAN 

Fan & Cone Installation

 

When this fan is used in a life support ventilation 

system where failure could result in loss or injury, 

the user should provide adequate backup 

ventilation or accept the risk of such loss or injury. 

IMPORTANT! 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BEFORE INSTALLING 

1.  Inspect fan for damage in transit. Check for 

loose, missing or damaged parts. 

2.  If there are any missing parts or if there is 

any shipping damage, do not attempt to 
operate fan. Contact your Distributor. 

 

MAINTENANCE 

1.  Read WARNING statements before proceeding. 
2.  Blades, motor and wire guards should be 

cleaned periodically to decrease vibration and 
ensure maximum fan life. Remove dirt with a 
dry brush or compressed air. DO NOT SPRAY 
MOTOR WITH WATER OR CLEANING FLUIDS. 

3.  Fan performance may be greatly reduced by 

damaged or dirty shutter. Clean and inspect 
shutter periodically to ensure maximum fan 
performance. 

4.  After using a Poultry Litter Treatment (PLT) 

near galvanized equipment, make sure there is 
no (PLT) residue on any galvanized surfaces, as 
it will lead to premature rusting. To clean 
galvanized surfaces, use a water based 
emulsifier, alkaline based cleaners with a pH of 
12 or lower or organic solvents. Then rinse the 
area with fresh water and wipe clean with a soft 
cloth. 

1.  Fan should be securely mounted to wall. Refer 

to mounting instructions on Section 4 of this 
manual. 

2.  The cone and wire guard must always be 

installed for your protection. 
National safety codes require that guards be 
installed if within 7' (2.1 m) of floor or within 
reach of personnel or livestock. 

3.  If thermostat is used, connect fan power cord to 

controller. 

INSTALLATION 

1.  Disconnect power source before installing or 

servicing fan. Failure to disconnect power 
source can result in property damage, 
serious injury or death. 

2.  When connected to an automatic controller, 

FAN MAY START AT ANY TIME. 

3.  IMPORTANT! Before Operating Fan, Inspect 

Fan For any Object That May Obstruct Blade 
Rotation. 

WARNING! 

Содержание Mega-Flow Panel

Страница 1: ...irty shutter Clean and inspect shutter periodically to ensure maximum fan performance 4 After using a Poultry Litter Treatment PLT near galvanized equipment make sure there is no PLT residue on any ga...

Страница 2: ...ev 03 2020 Date 09 22 20 Page 2 of 12 MEGA FLOW CON FAN Fan Cone Installation 1 Table of Contents Section Description Page 1 Table of Contents 2 2 Limited Warranty Protein Products 3 3 Framing Instruc...

Страница 3: ...paid for the product purchased This Warranty only covers the value of the warranted parts and equipment and does not cover labor charges for removing or installing defective parts shipping charges wit...

Страница 4: ...liers Electric or cordless drill 3 8 10 mm Socket 12 pt star Thread Locking Compound LOCKTITE 1 2 13 mm socket Figure 2 Fan Spacing with Cone Fan Housing Cone Center to Center Spacing Fan Size Spacing...

Страница 5: ...wall See Figure 3 NOTE Ensure the fan is raised to the top of the rough opening before housing is attached to the wall The top three screws should be attached first 2 Securely attach fan to wall with...

Страница 6: ...NG Incorrect motor rotation can damage fan internals and possibly cause injury Remove all electrical power after testing motor before proceeding with Fan installation 5 Assemble Cone 54 Cone 52 Cone 3...

Страница 7: ...be located on the outside of the cone assembly Do not tighten nuts Refer to Figures 6 8 d Once four 4 cone panels are assembled stand assembly up on large radius side Refer to Figure 5 e Pull both end...

Страница 8: ...ge bolts in each mounting bracket NOTE Make sure bottom panel with drain hole is closest to the ground b Bend the mounting brackets back slightly to help clear the area of the cone edges Mount cone to...

Страница 9: ...t the bolts from the inside of the cone through the mounting brackets See Figure 10 d Tighten 1 4 20 cone assembly nuts and bolts e For 36 52 and 54 Fans Install the Outside Fan Guard using four 3 8 x...

Страница 10: ...utter in place manually open vanes of shutter to access latch Fasten latch located inside fan housing into slot in flange of shutter Firmly lock down latch Repeat procedure to latch opposite side of s...

Страница 11: ...Cumberland 1004 E Illinois St Assumption IL 62510 PHONE 1 217 226 4421 FAX 1 217 226 4420 Manual Part No 4801 5323 Rev 03 2020 Date 09 22 20 Page 11 of 12 MEGA FLOW CON FAN Fan Cone Installation...

Страница 12: ...Assumption IL 62510 PHONE 1 217 226 4421 FAX 1 217 226 4420 Manual Part No 4801 5323 Rev 03 2020 Date 09 22 20 Page 12 of 12 MEGA FLOW CON FAN Fan Cone Installation Copyright 2020 by The GSI Group LLC...

Отзывы: