11.3. Alarm Settings
1. Select:
Main menu
Start/Stop*
Alarms
* A password may be required to access this menu.
Alarm Settings
Use to navigate
Temperature Alarms
Clean Mode
32.0 °F
Low Alarm
60.0 °F
High Alarm
90.0 °F
Critical Alarm
100.0 °F
Water 1 Spill Limit
100 Lit
Water 2 Spill Limit
100 Lit
Static Pressure Alarm
Low Alarm
.010 “WC
High Alarm
.100 .WC
Delay
300 sec
Feed Monitoring?
Yes
Feeder 1 Max Time
5 min
Feeder 2 Max Time
None min
Activate the alarm relay with
Lo Temperature
Yes
Hi Temperature
Yes
Defective sensor
Yes
Pot. Defective
Yes
Whisker switch
Yes
2. Set the following parameters:
(Refer to the previous section to get further informa-
tion on these parameters)
Temperature Alarms
Clean mode —
Set the temperature below
which a temperature alarm is set off in clean
mode.
Lo/Hi alarm —
Set the room temperature below
and above which a temperature alarm is set off.
Critical temperature —
Set the absolute
temperature above which an alarm is set off.
*
This parameter is accessible if an outside tempera-
ture probe is enabled (section 4.7.1).
Water spill limit —
Specify the maximum
amount of water that can be consumed
by each water meter per 15 minutes (1-
10,000 gal or liters/15 min). *
This parameter
is accessible if a water meter is enabled (sec. 4.7.1)
Static pressure limit
*Accessible if a SP probe is enabled (section 4.7.1).
Low / High alarm —
Set the pressure levels
below and above which an alarm is set off.
Delay —
The high or low pressure condition
must be maintained on this period of time
before the controller sets off the alarm. Set
the static pressure alarm delay to the desired
value (in seconds).
Feeder monitoring —
Select
“Yes”
if you want
the controller to monitor the run time of feed-
ing inputs. If this alarm condition is enabled,
set the maximum run time of each feeder (in
minutes). Refer to section 4.8 to assign the
relay that must open in case of a run time
alarm. *
This parameter is accessible if feeders are
enabled (section 4.5).
Activate the alarm relay —
Select
“Yes”
if you
want the controller to activate the alarm relay
when the following alarm conditions occur:
-
Lo / Hi Temperature
-
Lo / Hi Static pressure
-
Water spill
-
Defective sensors: temperature, humid-
ity, static pressure)
-
Comm. error with the RP-16/RP-32/WME-8
-
Defective potentiometer
-
Defective Whisker switch
[Alarm conditions that activate the alarm relay are
common to all programs].