0-10V For Min Vent ? —
Select
“Yes”
to use
the 0-10V fan output in minimum ventilation
or select
“No”
to disable this function. Refer
to section 6.2.4 for further information on this
type of output. *
This parameter is accessible if a
0-10V ventilation output is enabled above and it is
common to all programs.
Curtain compensation —
Select
“Yes”
to en-
able a compensation on the opening of natural
ventilation curtains as a function of the out-
side temperature. *
This parameter is accessible
if natural ventilation curtains are enabled above
and if an outside temperature sensor is enabled in
section 4.7.1.
Whisker switch —
Whisker switches tell the
controller when natural ventilation curtains
are sufficiently opened. Select
“Yes”
to enable
the whisker switch input of each curtain or
select
“No”
if these switches are not used.
*
[This parameter is common to all programs].
Ramping in stage 1 —
Select
“Yes”
to activate
the ramping function on stage 1 fans. This
function allows smoothing out transition
between minimum ventilation cycles and
stage 1.
Purge —
The purge function allows opening
natural ventilation curtains on a short period
of time to purge the air continuously. Select
“Yes”
to enable this function.
Misting —
The controller can control one mist-
ing output. Select
“Yes”
to enable this output.
Misting output follows the set point —
Op-
erating temperatures of the misting output
can either be related to the set point – which
means the controller automatically adjusts
them when the set point changes – or they
can be set as absolute values. Select
“Yes”
if they follow the set point or select
“No”
if
they set as absolute values. *
This parameter
is accessible if the misting output is enabled above.
[This parameter is common to all programs].
Cool cells —
The controller can control one
cool cell output. Select
“Yes”
to enable this
output.
Backup relay —
The controller can control
one backup relay. Select
“Yes”
to use a
backup relay. *
[This parameter is common to all
programs].
Use RP-16 / Use RP-32 —
It is possible to
connect one (1) external relay panel to the
controller. If required, enable the proper type
of panel: RP-16 or RP-32.*
[This parameter is
common to all programs].
Use age-based functions ? —
Some functions
of the controller are based on the age of the ani-
mals (temperature curve, controller programs
and lighting programs). Select
“Yes”
to use age-
based functions or select
“No”
to disable them.
*
[This parameter is common to all programs].
Temperature curve —
The temperature curve
is used to change the temperature set point
over time. Select
“Yes”
to use this curve. *
This
parameter is accessible if age-based functions are
enabled above. [This parameter is common to all
programs].
Number of programs —
The controller can
use several temperature programs. Enable the
desired number of programs (1 to 3 programs)
*
[This parameter is common to all programs].
Switch program by Age / Out T° ? —
The
controller can automatically enable a new
program when the animals reach a certain age
and/or as a function of outside temperature.
Specify what factor causes a change in the
program selection: “Age” and/or “ Out T” .
Answer
“No”
to both questions if you do no
want the controller to change the program
automatically. *
[These parameters are common
to all programs].
Use password? —
Select
“Yes”
to enable the
password protection or
“No”
to disable it.
*
[This parameter is common to all programs].
Installation
Use to navigate
0-10V For Min Vent ?
No
Use Curtain 1 Compens?
Yes
Use Curtain 1 Whisker?
Yes
Use Curtain 2 Compens?
Yes
Use Curtain 2 Whisker?
Yes
Use Ramping in Stage1?
Yes
Use Purge?
Yes
Use Misting?
Yes
Mist Follow Set Point?
Yes
Use Cool Cell?
Yes
Use Backup Relay
Yes
Use RP-16
No
Use RP-32
Yes
Use Age?
Yes
Use Temperature Curves?
Yes
Number of Programs
3
Switch Program by Age
Yes
Switch Program by OutT
Yes
Use Password?
Yes
Use Password Level
User 1
Clear Alarm Log?
No
Digit Display
T°
Use password level —
Select the default user
level used by the controller (user 1, user 2 or
installer). *
This parameter is accessible if the pass-
word protection is enabled above. [This parameter
is common to all programs].
Clear alarms? —
Select
“Yes”
to reset the
alarm log. *
This parameter is common to all
programs].
Digit display —
Select what piece of informa-
tion must be shown on the red LED display:
T°
: temperature;
SP
: static pressure;
T°/SP : temperature alternating
with the static pressure;
*[This parameter is common to all programs].