2. Installation
10
PNEG-2348
IR Hopper Sensor Installation
Mounting and Wiring the Control Box
The i-Plus3 control box needs to be wired in parallel to the junction box.
1. Mount the (C2000822) i-Plus3 control box to the ceiling near the junction box.
2. Supply 240V AC earth/ground (green), neutral L2 (white) and 240V L1 (black) to the correct leads.
3. Wire the signal wire sensor N.O. (red) in parallel with the other drop tube units to the control unit
(FLX-5350). This will close the loop and provide the control unit with a signal when any of the hoppers
calls for feed.
Figure 2B
Wiring the i-Plus3 Control Box
To Junction Box
To
IR Hopper Sensor
Junction
Box
i-PLUS3 CONTROL BOX (C2000822)
BLACK
Sensor NO (Red)
Sensor NO (Red)
FLX-5350
Junction
Box
EAR
TH (Green)
L2 (White)
Sensor NO (Red)
WHITE
RED
BLUE
L1 (Black)
1
ON
2
3
4