Program Data Input
There are a few items to note to help you program the Culligan® Premier Series Automatic Deionizer.
Slew Rates
This term refers to the speed at which the display moves through the input of material. For ex-
ample, holding down
for five (5) seconds when changing the Set Hour setting will increment
the number faster. Pressing the
or
for shorter intervals (fewer than five (5) seconds) will
slow the rate.
Programming Mode
Timeout
If there is no keypad activity for a one-minute period while in programming mode, the deion-
izer controller will exit programming mode and display the home screen. Any setting that was
changed prior to the controller timing out will revert to its original value. Press
to save the
setting.
Program Input
Acceptance
Press
to select a value to make it changeable,
or
to change, and press
again to
accept a selected setting value. (You must press
prior to programming mode timeout.)
Menu Lockout
It is possible to lock the keypad of the Premier Series Automatic Deionizer controller so that users will have access only to
the MANUAL REGEN, SET DATE/TIME, and DIAGNOSTICS menus.
SERVICE 1
LOCKED
JAN-01-11 12:01P
The system can be locked from the home screen. Press
and
simultaneously
and holding them down for 10 seconds until you see the word LOCKED.
SERVICE 1
UNLOCKED
JAN-01-11 12:01P
Repeating this process will unlock the keypad.
NOTE Menu lockout may only be completed from the home screen.