114
Culligan® Series M2 Reverse Osmosis
114
Cat. No. 01023095
First Time Setup with Wireless Remote, High and Low Float Switches
Press
to select a setting. Press
or
to change the setting. Press
to save. Press
to exit from a menu.
Select Language
LANGUAGE
ENGLISH
Select the controller language.
FIRST TIME SETUP
PRESS DOWN ARROW
From the FTS screen, press
to scroll to the date/time
settings.
Set Up Date
SET
MONTH
JAN
Set the Month, Day, and Year.
SET
DAY
1
SET YEAR
2012
Set Up Clock Type and Time
CLOCK TYPE
12 HR
Select either a 12-hour clock
(12:00A–11:59P) or 24-hour
clock (00:00–23:59)
SET HOUR
12PM
NOTE 24-hour clock
format does not
require AM or PM
SET
MINUTES
1
Set Up System Status at Startup
POWERON MODE
OFFLINE
Select the system status at
startup—offline or running. You
can change status after setup.
Set Up Units of Measure/Initialize System
SYSTEM UNITS
US INCH
Select METRIC for units out-
side the United States.
RUNNING
JAN-01-12 12:01P
The “home” screen displays
the RUNNING or OFFLINE
status of the RO system.
Set Up GROC-Remote Communication
>1)WIRELESS REM
2)MODEM
3)FLOW METERS
4)SWITCH INPUTS
From the main menu, select
4)SETUP —> 5)ACCESSO-
RIES —> 1)WIRELESS REM
.
WIRELESS REM
NOT INSTALLED
Change the setting to
INSTALLED
.
CHANNEL #
1
Select the channel to com-
municate between the remote
and the RO controller.
RF FREQUENCY
915MHz
Select the radio frequency:
915MHz for North America,
869 or 933 in other locations.
Set Up Float Switches
2)LANGUAGE
3)POWERON MODE
4)FLUSH MODES
>5)ACCESSORIES
From the
SETUP
menu, select
5)ACCESSORIES
.
1)WIRELESS REM
2)MODEM
3)FLOW METERS
>4)SWITCH INPUTS
Select
4)SWITCH INPUTS
.
FLOAT SWITCHES
NORMALLY OPEN
Scroll to the
FLOAT SWITCH-
ES
setting; select
NORMALLY
OPEN
.
FS Hi
Delay
10
MINUTES
Select how long the float
switch stays closed after tran-
sitioning from high to low level.
Press
to save the settings and return to the
home screen.
Set Up GROC-Remote Communication
>1)RF SETUP
2)MODEM SETUP
From the main menu, select
2)SETUP —> 1)RF SETUP
.
CHANNEL #
1
Select the SAME channel to
communicate that is set on the
RO controller.
RF FREQUENCY
915MHz
Select the radio frequency:
915MHz for North America,
869 or 933 in other locations.