Data Port Output
111
Cat. No. 01023095
*** MINI REPORT ***
FM1 = 0.00
FM2 = 0.00
PI-PO = 0
Operational Status = OFFLINE
Recovery Rate = 0.0 %
Rejection Rate = 76 %
Float Switch Hi = active
Float Switch Low = active
Total FM1 = 0
Total pump on = 0 hrs
Units = Inch
FM1 Meter Factor = 80.0
FM2 Meter Factor = 80.0
Max press dif limit = 250
Min reject % limit = 20 %
Max recovery % limit = 90 %
Min recovery % limit = 10 %
Max IN temp limit = 120
Min IN temp limit = 33
Max feed pressure limit = 250
Min feed pressure limit = 50
Max TDS Out limit = 250
Max pump time hrs/day limit = 0
Min NORM flow limit = 0
NORM flow std pressure limit = 120
Startup flush = OFF --
Standby flush = OFF --
Time trigger flush = OFF -- --
Flow trigger flush = OFF -- --
Quality flush = ON 3 10
Permeate flush = OFF --
TDS probe = both
*** Historical Data ***
Month = JAN
Year = 2012
Rejection = 0 %
Recovery = 0.0
PI-PO = 0
NFlow = 0.0
Total Water = 0
Product PPM = 0
Figure 65.
Data report from GBE RO Controller.
If you do not see the report, check your settings and make sure the cables are firmly connected. If you still don’t see the
report, try some of the other COM ports.
The status message on the screen is updated every minute and will look similar to this:
CULL,009.30,004.60,1,050,096,0,0,00050202,00000,00000,00000,000,000,000,1023111027
This message was described at the beginning of this Appendix.