Performance Specifications
3
Cat. No. 01024821
Performance Specifications
Specifications for High Efficiency 1.5 Twin Water Softeners
Culligan commercial water softeners are designed to remove hardness minerals from water. In order to function properly,
some operational parameters must be followed. They include:
1. An operating water pressure between 20 and 125 psi (138-862 kPa). If water pressure is greater than 80 psi, Culligan
recommends following the IAPMO Uniform Plumbing code section 806.2 by installing a Pressure Regulating Valve
before the system. Operating on high presure for extended periods of time can increase the service frequency of re-
placement parts. If water pressure can drop below the minimum water pressure, add a booster pump to maintain a
25 psi (172 kPa) minimum operating pressure.
2. Operating temperature between 33° and 120°F or 1°–49°C.
3. Clear (non-turbid) water supplies (Less than 5 NTU).
Table 1. HE 1.5 Twin Specifications (U.S. units).
Model
No.
Exchange Capacity
(kgr) Per Tank
Service Flow Rate
(gpm) Per Tank
Backwash
Flow Rate
(gpm) Per
Tank
Minimum
System WxHxD
Dimensions (in.)
Maximum
(grains)
Minimum
(grains)
Continuous
@ 15 psi max.
pressure loss
Peak @ 25
psi. max.
pressure loss
HE-060
60
40
25.1
31.5
5.5
58x60.1x16
HE-090
90
60
26.6
35.2
5.5
68x62.7x20
HE-120
120
80
23.3
31.8
5.5
68x74.7x20
HE-150
150
100
27.2
35.8
7
72x76.3x21
HE-210
210
140
28.0
37.4
11.5
78x77x23
Table 2. HE 1.5 Twin Specifications (Metric units).
Model
No.
Exchange Capacity
(kgr) Per Tank
Service Flow Rate (lpm)
Per Tank
Backwash
Flow Rate
(l/min) Per
Tank
Minimum
System WxHxD
Dimensions (cm)
Maximum
(grains)
Minimum
(grains)
Continuous
@ 1 bar drop
Peak @ 1.7
bar drop
HE-060
60
40
95.1
140.0
20.8
147x152x41
HE-090
90
60
100.8
143.8
20.8
173x157x51
HE-120
120
80
88.3
132.5
20.8
173x188x51
HE-150
150
100
103.1
135.5
26.5
183x193x53
HE-210
210
140
106.0
141.6
43.5
198x196x58
NOTE Dimensions assume systems include an optional, standard size brine tank. The measured width in-
cludes the supplied interconnecting pipe.
NOTE Allow a minimum of 24" above the overall system height for access into the top of tank(s).