Manufacturer:
Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847)
430-2800
Product:
Gold Arsenic 14”
Testing Conditions & Results:
Capacity:
200,000 gal (772,000 L)
Pressure:
60 psi
Temperature:
63°- 73° (17° - 23°C)
Service Flow:
9.5 gpm @ 15 psi, 36.67 Lpm @ 15 psi
Operating Conditions:
Operating Temperature Range:
33 - 120°F (1 - 49°C)
Water Pressure Range:
20 - 120 psi (138 - 862 kPA)
Water Pressure Range (Canada):
20 - 90 psi (138 - 621 kPA)
Electrical Characteristics:
24V/50-60 Hz, 45 Watts
Substance Reduction
Testing was performed under standard laboratory conditions, actual performance may vary. This system has been
tested according to NSF/ANSI 53 for reduction of the substances listed below. The concentration of the indicated sub-
stance in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 53.
Model
Substance
Influent Challenge
Concentration
mg/L
Maximum Permissible
Product water
Concentration mg/L
Minimum
Reduction
Average
Reduction
Gold Arseinc
14”
Trivalent Arsenic pH 6.5
0.050 + 10%
0.010
95.9%
98.7%
Trivalent Arsenic pH 8.5
0.050 + 10%
0.010
95.9%
98.7%
Pentavalent Arsenic pH 6.5
0.050 + 10%
0.010
95.9%
98.7%
Pentavalent Arsenic pH 8.5
0.050 + 10%
0.010
95.9%
98.7%
The Culligan Gold Arsenic 14” has been tested and certified by WQA against NSF/ANSI Standard 372, CSA
B483.1, and NSF/ANSI Standard 53 for the reduction of arsenic (pentavalent and trivalent) up to 200,000 gallons.
The concentration in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 53.
Performance Indicator: If water flow decreases or a notable taste change occurs, the filter should be backwashed. If
conditions do not improve, contact your local Culligan Man. He can determine if your filter requires servicing. Do not
use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the
system. Refer to the specifications and warranty sections of this owners guide for more specific product information.
To avoid contamination from improper handling and installation, your system should only be installed and serviced by
your Culligan Man. Performance will vary based on local water conditions. The substances reduced by this product
are not necessarily in your water.
This system has been tested for the treatment of water containing pentavalent (also known as As(V), As(+5), or arse-
nate) and trivalent arsenic (also known as As(III), As(+3), or arsenite) at concentrations of 0.050 mg/L or less. This
system reduces both forms of arsenic below EPA MCL. Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
The arsenic removal component of this system must be replaced at the end of its useful life of 200,000 gallons for the
Culligan Gold Arsenic 14” . The replacement of the removal component can be purchased from your local Culligan
dealer.