Culligan Aqua-Cleer MFP 4-44-MD 1200 Скачать руководство пользователя страница 1

Culligan reserves the right to change the specifications given in this manual at any time. 

CULLIGAN ITALIANA

 S.p.A. 

Via Gandolfi, 6 - 40057 Cadriano di Granarolo E. BO (ITALY) 

Tel. +39.051.6017.111 – fax +39.051.765.602 

Company with UNI EN ISO 9001 certified quality system

 

 

M006-06 

Rev. 01 – 05/2012 

 
 
 
 
 

 
 

Aqua-Cleer 

MFP 4–44 MD 

 

Model 400-800-1200 

1600-2200-2800-3300 

 

 

USER’S 

TECHNICAL MANUAL 

 
 
 

MEDICAL DEVICE

 
 
 
 

 0434

 

Содержание Aqua-Cleer MFP 4-44-MD 1200

Страница 1: ...GAN ITALIANA S p A Via Gandolfi 6 40057 Cadriano di Granarolo E BO ITALY Tel 39 051 6017 111 fax 39 051 765 602 Company with UNI EN ISO 9001 certified quality system M006 06 Rev 01 05 2012 Aqua Cleer...

Страница 2: ......

Страница 3: ...and storage requirements of the current regulations The water produced by every unit must only be used for its specifically intended purpose Culligan declines any liability for the consequences of imp...

Страница 4: ......

Страница 5: ...CAL CHARACTERISTICS 3 DESCRIPTION OF SUPPLY 4 LABELING AND IDENTIFICATION 4 INSTALLATION 6 DESCRIPTION OF ELECTRONIC PANEL KEYBOARD 6 OPERATION FOR USER WATER PRODUCTION 6 CONTROLS AND ADJUSTMENTS 7 S...

Страница 6: ......

Страница 7: ...pm Max salinity Aqua Cleer MFP 4 44 MD model from 2200 to 3300 1500 mg l TDS in ppm Temporary hardness 35 f S D I 3 pH 7 1 Chlorine 0 2 ppm Iron 0 1 ppm Manganese 0 05 ppm Calcium Sulfate concentratio...

Страница 8: ...ns water temperature 10 C operating pressure 200 or 261 psi 14 or 18 bar according to the models reject recirculation completely closed and no longer new modules DESCRIPTION OF SUPPLY Components 1 mai...

Страница 9: ...er 7 symbol indicating water temperature operating limits 8 date of manufacture 9 type of marking 10 equipment operating voltage 11 equipment operating frequency 12 number of phases necessary for equi...

Страница 10: ...VELY BY AUTHORIZED SERVICE CENTER TECHNICIANS DISPLAY The MFP 4 44 MD has a multifunction display able to provide the user with all useful information on machine operation in real time ATTENTION UP an...

Страница 11: ...continuously RECOMMENDED SANITIZING CHEMICALS AND THEIR CONCENTRATION PERESAL with max permissible concentration of 0 2 in at least softened water ALARMS LOW FEED WATER PRESSURE the display shows WAR...

Страница 12: ...PARTS WHICH ARE THE ONLY ONES ALLOWED FOR CORRECT OPERATION OF THE EQUIPMENT THE OWNER OF THE EQUIPMENT IS ADVISED TO STIPULATE SPECIFIC MAINTENANCE CONTRACTS WITH CULLIGAN ITALIANA S p A OR AUTHORIZ...

Страница 13: ...elp prevent electromagnetic interference by ensuring a minimum distance between RF mobile and portable communication equipment transmitters and theAQUA CLEER MFP 4 44 MD as recommended below in relati...

Страница 14: ...bable panel electronic board fault Contact the Authorized Culligan Service Center that carried out installation The equipment is blocked and does not restart although not displaying alarm signals Prob...

Страница 15: ...UCTIVITY CHECK INLET MONTHLY Main and extraordinary maintenance to be carried out by the CULLIGAN SERVICE CENTER date signature PRODUCT date signature REJECT date signature S D I TEST date signature E...

Страница 16: ...12 Aqua Cleer MFP4 44 MD User M006 06 Rev 01 05 2012...

Отзывы: