www.cuesinc.com
,
20
CUES Inc.
,
Currahee Cutter User Manual | CK902
CUES Inc.
,
Currahee Cutter User Manual | CK902
21
SYSTEM SETUP & INSTALLATION
4
a. Attach the air motor housing as required for size of pipe being reinstated as
shown below.
b. Apply anti-seize thread lubricant and torque screws to 7 ft-lbs.
c. Dual camera assembly can be rotated up for ease of access.
d. Attach air hose from Cutter to air motor housing.
NOTE: Air hose can be
detached from air motor housing when rotating camera assembly up to
prevent pinching.
e. Suggested housing sizes are as shown on the Currahee Cutter Quick Card,
P/N CK901.
3
3a
STEP 3c.
Rotate dual camera assembly
upwards for ease of access.
STEP 3b.
Apply anti-seize thread lubricant and
torque screws to 7 ft-lbs. (4 places - 2
on the opposite side).