up and down or turning it slowly. It can be done more easily if you insert the nozzle management
pin by considering the distance between the filament inlet and the tip of the nozzle.
④
Once the removal of foreign substances in the nozzle is done to some degree, wait a while in
the state where the temperature of the nozzle is raised, and repeat the cleaning of the foreign
substances as in
③
. This is to remove the foreign substances that have been melted down by
waiting until the foreign substances that had been adhered to the inner wall of the nozzle to melt
down.
⑤
Insert the filament to be used by melting it into the nozzle by Loading/Unloading the filament,
and repeat the processes from
①
. This is to remove the foreign substances by adhering them to
the normal filament that has been melted.
If the filament doesn’t get discharged (if the filament doesn’t get pushed out as it is melted) or the
printing quality is poor even after the use of the nozzle management pin, replace the nozzle since
the nozzle has been damaged. Contact the designated service center for the replacement of the
nozzle
4. Cautions regarding the Use of the nozzle Management Pin
Proper use of the nozzle management pin would be very helpful for the management of the nozzle.
However, since the nozzle management pin goes through the passage in the Extruder that the filament
goes through when the nozzle management pin is used, it may cause damage or pollution in the inside of
the Extruder, which may lead to the breakdown of the Extruder or make the clogging of the nozzle even
more severe. Since the breakdown of the Extruder due to the improper use of the nozzle management pin
as shown below would become a reason for the charged repair, be cautious.
①
Occurrence of Clogging due to Damage of the Device
If the nozzle management pin is excessively used, it may damage the device in the passage or
cause the clogging of the nozzle as the device gets cut off by the nozzle management pin and
falls into the nozzle. Since it is difficult to clear the clogging of the nozzle that has occurred in
such way, the entire nozzle needs to be replaced, and therefore, be cautious not to damage the
device inside.
②
Secondary Pollution Due to Residues that Are Attached on the Nozzle
Management Pin
If the nozzle management
pin is used, a filament residue would be attached to the tip of the
nozzle management pin, and the nozzle management pin or the filament may not be able to be
inserted as the filament residues adhere to the inlet of the nozzle or the filament passage in the
inside of the Extruder while taking out the nozzle management pin. In order to prevent the
55