ELECTRICAL SYSTEM
94
Key switch
The Key Switch is similar to those used in a variety of
MTD applications since 1999. The difference in this
case is that it is incorporated in the same housing as
the RMC module; the two items are not available sepa-
rately. See Figure 7.1.
1.
In the
OFF
position, continuity can be found
between the M, G, and A1 terminals.
See Figure 7.2.
•
M is connected to the magneto by a yellow wire,
G is connected to ground by a green wire, and
A1 is connected to the after fire solenoid.
NOTE:
In the
OFF
position, the magneto primary
windings are grounded, disabling the ignition
system. The altenator output is shorted to
ground and the after fire solenoid looses its
power from the B terminal. This turns-off the fuel
supply.
•
Symptom
-engine runs with key in OFF position:
The key switch is not completing the path to
ground either because of an internal fault or a
bad ground connection elsewhere in the har-
ness. Check continuity between M, G, and A1
terminals with key switch in OFF position.
Check green wire for continuity to ground.
•
Symptom
-loud “BANG” when key is turned to
the OFF position: The after-fire solenoid is not
closing, either because it is physically damaged
or the power is not being turned off. Check for
power at the solenoid. Check continuity between
G and A1 terminals. Check for no continuity
between A1 and the B terminals.
NOTE:
If the engine is at an idle when the key is
turned off, fuel is drawn into the engine through
the idle ports of the carburetor by-passing the
fuel shut off solenoid. The raw fuel will travel
through the engine and ignite in the muffler
causing an after fire.
•
Symptom
-Engine runs 3-5 seconds after key is
turned to OFF position: The after-fire solenoid is
turning-off the fuel supply, but the ignition is con-
tinuing to operate. Check continuity between the
M and G terminals in the OFF position. Check
continuity from yellow wire connection all the
way to the spade terminal on the magneto.
2.
In the
START
position, continuity can be found
between B, S, and A1 terminals.
•
Battery power from the B terminal is directed to
the start circuit through the S terminal and to the
after fire solenoid through A1.
Figure 7.1
Key Switch
RMC Module
Figure 7.2
L
S
B
G
A1
A2
M
L
S
B
G
A1
A2
M
L
S
B
G
A1
A2
M
L
S
B
G
A1
A2
M
Off
Start
Run w/RMC
Run
Key Switch Schematic
Содержание 900 series
Страница 2: ......
Страница 6: ......
Страница 12: ...ENGINE RELATED PARTS 6 ...
Страница 62: ...HYDRO DRIVE AND BRAKE SYSTEM 56 ...
Страница 98: ...CVT Drive and brake system 92 ...
Страница 135: ...ELECTRICAL SYSTEM 129 Schematics LECTRIC 04 ...
Страница 136: ...ELECTRICAL SYSTEM 130 ANUAL 04 ...
Страница 152: ...Cutting Decks And Lift Shaft 146 ...
Страница 157: ...APPENDIX 151 This Hydro Gear manual is reprinted in its entirety with permission from Hydro Gear HYDRO GEAR APPENDIX ...
Страница 158: ...APPENDIX 152 ...
Страница 165: ...310 0510 IHT 5 MODEL RECOGNITION 618 0319 166768 104 1760 173839 036932 618 0389A ...
Страница 190: ...310 0510 IHT 30 310 0710 EXPLODED VIEW ...
Страница 192: ...310 0510 IHT 32 310 0610 EXPLODED VIEW ...
Страница 194: ...310 0510 IHT 34 310 0510 EXPLODED VIEW 6 SEALANT 57 20W 50 OIL 127 SEAL O RING KIT ...
Страница 198: ...310 0510 IHT 38 2008 HYDRO GEAR Printed in U S A Rev P1 ...