310-0510 IHT
11
PURGING PROCEDURES
Due to the effects air has on efficiency in
hydrostatic drive applications, it is critical that it
be purged from the system.
These purge procedures should be imple-
mented any time a hydrostatic system has
been opened to facilitate maintenance or any
additional oil has been added to the system.
Air creates inefficiency because its compres-
sion and expansion rate is higher than that of
the oil approved for use in hydrostatic drive
systems.
The resulting symptoms in hydrostatic systems
may be:
1. Noisy operation.
2. Lack of power or drive after short term
operation.
3. High operation temperature and excessive
expansion of oil.
Before starting, make sure the transaxle/
transmission is at the proper oil level. If it is
not, fill to the specifications outlined on page
10, Figure 4.
The following procedures should be performed
with the vehicle drive wheels off the ground,
then repeated under normal operating condi-
tions.
1. With the bypass valve open and the engine
running, slowly move the directional control
in both forward and reverse directions
(5 to 6 times), as air is purged from the unit,
the oil level will drop.
2. With the bypass valve closed and the
engine running, slowly move the directional
control in both forward and reverse
directions (5 to 6 times). Check the oil level,
and add oil as required after stopping
engine.
3. It may be necessary to repeat Steps 1 and 2
until all the air is completely purged from the
system. When the transaxle moves forward
and reverse at normal speed purging is
complete.
Содержание 900 series
Страница 2: ......
Страница 6: ......
Страница 12: ...ENGINE RELATED PARTS 6 ...
Страница 62: ...HYDRO DRIVE AND BRAKE SYSTEM 56 ...
Страница 98: ...CVT Drive and brake system 92 ...
Страница 135: ...ELECTRICAL SYSTEM 129 Schematics LECTRIC 04 ...
Страница 136: ...ELECTRICAL SYSTEM 130 ANUAL 04 ...
Страница 152: ...Cutting Decks And Lift Shaft 146 ...
Страница 157: ...APPENDIX 151 This Hydro Gear manual is reprinted in its entirety with permission from Hydro Gear HYDRO GEAR APPENDIX ...
Страница 158: ...APPENDIX 152 ...
Страница 165: ...310 0510 IHT 5 MODEL RECOGNITION 618 0319 166768 104 1760 173839 036932 618 0389A ...
Страница 190: ...310 0510 IHT 30 310 0710 EXPLODED VIEW ...
Страница 192: ...310 0510 IHT 32 310 0610 EXPLODED VIEW ...
Страница 194: ...310 0510 IHT 34 310 0510 EXPLODED VIEW 6 SEALANT 57 20W 50 OIL 127 SEAL O RING KIT ...
Страница 198: ...310 0510 IHT 38 2008 HYDRO GEAR Printed in U S A Rev P1 ...