ELECTRICAL SYSTEM
101
•
Circuitry
: When the key switch is in the
REVERSE CAUTION MODE position, a ground
path is established by connecting terminal A2 to
terminal L within the key switch. The white wire
from the RMC module connects to A2, and a
green ground wire connects to L.
•
Interpretation
: If the white wire fails to reach a
ground path when the key switch is in the
REVERSE CAUTION MODE position, the RMC
module will not arm or operate. Check the key
switch for continuity between A2 and L in the
REVERSE CAUTION MODE position, confirm
that the green wire connecting to the L terminal
does have good continuity to ground, and check
for any loss of continuity in the white wire that
extends from the key switch to the RMC module,
including the molded connector between the two
components.
9.
If the RMC plug test indicates fault with any of
the safety switches, the next step is to test the
suspect switch. The operation of those switches
is described in the following sections.
Electric PTO switch
Understanding the electric PTO switch
•
In A-Com, power is supplied to the PTO switch
from the A1 terminal of the ignition switch
through a red wire. when the PTO switch is
turned on this completes the circuit to allow
power to go to the PTO clutch. It is a normally
opened (NO) set of contacts.
•
B-COM is in the safety shut-down circuit. It is a
normally opened (NO) set of contacts. A circuit is
completed from the NO terminal on the PTO
relay through the white wire with black trace to
the E-PTO terminal on the RMC module and the
PTO relay coil through the yellow wire with black
trace when the contacts are closed. This gives
the RMC module the ability to turn-off the PTO
clutch.
•
C-COM is in the starter inhibit circuit. It is a nor-
mally closed (NC) set of contacts. When the
PTO is OFF, and the contacts are closed, power
coming from the brake switch (key switch in
START, brakes ON) through the orange wire
with black trace is passed on to the trigger termi-
nal on the starter solenoid through the orange
wire with white trace.
NOTE:
The top terminals are showing normally
closed at rest and the middle terminals are nor-
mally open at rest
NOTE:
There are three contacts on the right side
in the C-COM. For this application the normally
opened (NO) contact is used.
Figure 7.9
Содержание 900 series
Страница 2: ......
Страница 6: ......
Страница 12: ...ENGINE RELATED PARTS 6 ...
Страница 62: ...HYDRO DRIVE AND BRAKE SYSTEM 56 ...
Страница 98: ...CVT Drive and brake system 92 ...
Страница 135: ...ELECTRICAL SYSTEM 129 Schematics LECTRIC 04 ...
Страница 136: ...ELECTRICAL SYSTEM 130 ANUAL 04 ...
Страница 152: ...Cutting Decks And Lift Shaft 146 ...
Страница 157: ...APPENDIX 151 This Hydro Gear manual is reprinted in its entirety with permission from Hydro Gear HYDRO GEAR APPENDIX ...
Страница 158: ...APPENDIX 152 ...
Страница 165: ...310 0510 IHT 5 MODEL RECOGNITION 618 0319 166768 104 1760 173839 036932 618 0389A ...
Страница 190: ...310 0510 IHT 30 310 0710 EXPLODED VIEW ...
Страница 192: ...310 0510 IHT 32 310 0610 EXPLODED VIEW ...
Страница 194: ...310 0510 IHT 34 310 0510 EXPLODED VIEW 6 SEALANT 57 20W 50 OIL 127 SEAL O RING KIT ...
Страница 198: ...310 0510 IHT 38 2008 HYDRO GEAR Printed in U S A Rev P1 ...