User Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

User Guide: 

 

Chosen Techno Solar Private 
Limited Series 4 Module 

 

 

North America 

 

 

 

 

 

REV 3.1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

PD-5-200-04 NA | 0348_UG_NA_11JUL17 

Содержание FS-4100

Страница 1: ...User Guide User Guide Chosen Techno Solar Private Limited Series 4 Module North America REV 3 1 PD 5 200 04 NA 0348_UG_NA_11JUL17...

Страница 2: ...1 System Derating Factors 5 4 Installation 6 4 1 Mounting 6 4 2 Module Orientation 8 4 3 Module Shading Considerations 8 4 4 Electrical Interconnection 9 5 Mechanical Specifications Drawings 12 6 Prop...

Страница 3: ...lers and maintenance personnel Read this User Guide thoroughly before beginning any work related to the installation operation or maintenance of the Chosen Techno Solar Private Limited Series 4 or Ser...

Страница 4: ...Chosen Techno Solar Private Limited module reverse current overload may result in module failure including module breakage Extreme and continuous reverse current overload conditions may cause a fire...

Страница 5: ...ized or Listed by Underwriters Laboratories UL for their intended purpose Ensure the PV array open circuit voltage does not exceed 1500VDC 1000VDC for UL Canada Install modules with mounting systems t...

Страница 6: ...2 FS 4105 2 FS 4107 2 FS 4110 2 FS 4112 2 FS 4100A 2 FS 4102A 2 FS 4105A 2 FS 4107A 2 FS 4110A 2 FS 4112A 2 Nominal Power 5 PMPP W 100 0 102 5 105 0 107 5 110 0 112 5 Voltage at PMA X VMPP V 66 2 67...

Страница 7: ...tage VSYS V 1500 2 Maximum Series Fuse ICF A 4 0 1 As received and stabilized ratings at Standard Test Condition 1000W m2 AM 1 5 25 C Cell Temperature 10 2 1000V Listed for UL Canada 3 Measurement unc...

Страница 8: ...d using approved hardware in the manner specified by the mounting instructions in Chosen Techno Solar Private Limited Application Note PD 5 320 04 NA Additional mounting systems may be approved for us...

Страница 9: ...eight is 3 25 in 82 55 mm Modules used in UL Listed rooftop applications must be installed with approved mounting systems If alternate mounting means are employed this may affect the Listing fire clas...

Страница 10: ...from diffuse shading for objects greater than 2 meters or 7 feet There is a low risk of module damage due to shading from walking or standing in front of operating modules or from parking or driving...

Страница 11: ...lead wires tight at any time After installation the connected wire must not be under stress or tension Do not use junction box assembly or lead wire strain relief loops to secure excess wire or to be...

Страница 12: ...re inverter ratings are appropriate When connecting Chosen Techno Solar Private Limited Series 4 and or Series 4A Modules in a series string ensure that the system design voltage and inverter design s...

Страница 13: ...unded ungrounded floating and bi polar system architectures provided all appropriate design requirements are met and approved by First Solar FS Series PV Modules should not be used in positive grounde...

Страница 14: ...on Span2 1314 mm 51 73 in Weight 12 kg 26 5 lbs Fire Performance Type3 Type 10 Module Class A Spread of Flame Class B Burning Brand Operating Temperature 40 C to 85 C 1Minimum from strain relief to co...

Страница 15: ...ng in landscape orientation is acceptable Module row to row shading in portrait orientation is prohibited Strain relief cable ties must not be removed If module cleaning is undertaken modules must be...

Страница 16: ...visit www firstsolar com recycling for further details on the recycling program It is normal for the modules to exhibit visual irregularities which do not impact power Series 4A Modules with anti refl...

Страница 17: ...otice Accordingly the reader is cautioned to verify that data sheets are current before placing orders or finalizing system permitting and or design Information furnished by Chosen Techno Solar Privat...

Страница 18: ...Series 4 PV Module Mounting for UL Applications PD 5 308 FS Series PV Modules Reverse Current Overload PD 5 320 04 FS Series 4 PV Module Mounting PD 5 804 FS Series PV Module Cleaning Guidelines PD 5...

Страница 19: ...to 2 2 Section 4 1 1 Added comment to Section 7 on cleaning risk of damage 12 17 2017 Added Section 10 for Doc References Revised order of Warnings in Sections 2 3 Added electrical ratings for FS 4xx...