BULK CHARGING TIME
Battery capacity (Ah)
Time to ~80% charge (h)
2
1.5
8
6
20
20
32
36
SPECIFICATION
Model
1019
Voltage AC
100–120VAC,
50–60Hz. Output power is reduced at
lower input voltage.
Current
0.2A rms (at full charging current)
Back current drain*
<1mA
Charging voltage
7.2V, Nominal: 6V
Ripple**
Max
50mV rms, max 0.05A rms.
Charging current
0.8A max.
Battery cable fuse 5A
Ambient temperature
-4°F to +122°F. Automatic reduction of power at increased
ambient temperature.
Cooling
Natural convection. Do not cover the charger.
Charge cycle
UC 800 is a four-step fully automatic charger.
Type of batteries
All types of 6V lead-acid batteries (Wet, Maintenance Free,
AGM and most GEL).
Battery capacity
2 to 32Ah, up to 100Ah for maintenance.
Dimensions
5½ x 2 x 1½ inches (L x W x H)
Weight
0.7 lbs
*) Back Current Drain is what the charger uses to drain the battery if the power cord is
disconnected. The reverse current of the UC 800 is very low and corresponds to 1Ah per
month.
**) The ripple wave describes how many disturbances are exhibited by current and volt-
age. A rippled voltage can cause damage to other equipment connected to the battery.
The UC 800 supplies voltage and current with very low voltage rippling. This increases the
life of the battery and ensures that equipment connected to it will not be damaged.