8
Aerial work platform
B-LIFT 18 HV
COD. UM0287_GB | REV. 0.0 | ED: 09/18
GB
Chapter 6
PROCEDURES FOR USE
6.3.6
Returning the lifting platform to its rest position
Return the work platform to its rest position as follows (Fig. 6.5):
•
Retract the telescopic elements of the boom completely (3).
•
Rotate the work platform (4) to its central position (90° with respect to the boom).
•
Retract the extension completely, close the main boom (2), position the turret in the centre by
lining up the yellow markings (1), lower the telescopic boom until reaching the rest position.
•
Visually check that the boom is centred perfectly on its rest.
•
Get off the platform carefully.
•
Check that there are no objects inside the platform.
Fig.
6.5
6.3.7
Closing the stabilisers
•
Insert the key in the selector switch on the ground control panel and turn it to the “stabilisers”
position (Fig. 6.2, 9);
•
retract the stabilisers completely by operating the levers (Fig. 6.3, 1, 2, 3 & 4); retract the beams
completely by operating the levers (Fig. 6.3, 5);
•
check that the stabiliser indicator lights turn off (Fig. 6.2, 1, 2, 3 & 4);
•
rotate the key to the “neutral” position and remove it from the selector switch (Fig. 6.2, 9).
6.3.8
Switching off the vehicle
Sit in the driver’s seat (Fig. 6.1):
•
Check that the red indicator light on the control panel is off, indicating the successful retraction
of the stabilisers (7) and that the green indicator light is on, indicating that the machine is ready
to be moved (6);
•
Bring the manual accelerator control back to idle speed (unless the vehicle has an automatic
acceleration control)
Disengage the power take-off as follows (Fig. 6.1):
•
Depress the clutch pedal.
•
press the disengage button (2) or move the lever between the seats(1) to “DISENGAGE”;
•
Release the clutch pedal.
•
the red “power take-off” button (5) will switch off and the sound alarm will stop.