SB102 Series Switch Box
4-12 Channel
Product Manual
Страница 1: ...SB102 Series Switch Box SB102 Series Switch Box 4 12 Channel 4 12 Channel Product Manual Product Manual...
Страница 2: ...uct Description 3 Product Dimensions Diagram 4 Mounting Instructions 5 Conduit Entry 6 Grounding 7 Installation of Sensor signal Input Cable 8 Post Installation Testing 11 Warranty Return Information...
Страница 3: ...d a switched two pin MIL spec connector for data collection Input wiring from each sensor is connected to the outputs via quick connect or screw terminal blocks Each terminal block includes inputs for...
Страница 4: ...Location Card Two pin MIL Output Connector Switch Quick Connect Option Screw Terminal Option Optional Online Expansion Jack Input Terminal Strip Options BNC Output Connector Figure 1 Dimensions Figur...
Страница 5: ...ies provided you should add your own entry prior to mounting the switch box CTC does not recommend putting holes in the top of the enclosure due to access and moisture concerns CTC Vibration Switch Bo...
Страница 6: ...try enters from the bottom of the enclosure when mounted Note To ensure moisture will not flow into the enclosure a hole should be drilled at the lowest point in the conduit to provide drainage for an...
Страница 7: ...s grounded to earth ground A Mounting to Earth Ground When mounting SB102 Series Switch boxes to earth ground such as an I Beam mount the shield ground wire using a mounting bolt through one of the mo...
Страница 8: ...nd Figure 6 Ground Wire Placement Sensor Installation Installation of sensors signal input cable 1 Feed blunt end through the cable entry at the bottom of the enclosure Note it is recommended that cab...
Страница 9: ...Drain wire 4 Locate the appropriate plug identified by channel number remove the plug and install the wires using a small flathead screwdriver Push Plug back into location Orientation is as follows a...
Страница 10: ...ent location Figure 10 Connecting Cables to Switch Box CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 GND GND GND GND GND GND GND GND GND GND GND GND 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 1...
Страница 11: ...at the switch box while Person B will be located at the measurement location 2 Once positioned Person A will connect the TM1018 to the data collector output to the switch box and turn the Channel Sele...
Страница 12: ...ter 2 Yellow LED Open Circuit Indicates one of the following a Cable connector is not connected to accelerometer b Cable is open circuit broken or not connected one end c Accelerometer is not function...
Страница 13: ...condition within 90 days of shipment Build to order products qualify for a 50 refund if returned in new condition within 90 days of shipment Custom products are quoted and built specifically to the r...