61
CHAPTER 3
INTRODUCTION TO CLI
<guard_time_ms: 10-2000>: Specify the guard time. The allowed range is 10 to 2000 ms.
Negation:
(config)# no erps <group> guard
Show: #
show erps [ <groups> ] [ detail | statistics ]
3.9.12.2 (config)# erps <group> holdoff <holdoff_time_ms>
Syntax:
(config)# erps <group> holdoff <holdoff_time_ms>
Parameters:
<group: 1-64>: Specify a group number. The allowed range is from 1 to 64.
<holdoff_time_ms: 0-10000>: Specify the holdoff time. The allowed range is 0 to 10000 ms.
Explanation:
Configure the specified group’s holdoff time.
Negation:
(config)# no erps <group> holdoff
Show: #
show erps [ <groups> ] [ detail | statistics ]
3.9.12.3 (config)# erps <group> major port0 interface port1 interface <port_type> <port1>
[ interconnect ]
Syntax:
(config)# erps <group> major port0 interface <port_type> <port0> port1 interface <port_type> <port1>
[ interconnect ]
Explanation:
Create an ERPS instance.
Parameters:
<group: 1-64>: Specify a group number. The allowed range is from 1 to 64.
<port_type> <port0>: Specify Port 0’s port type and port number. Port 0 is also known as E port (East port) which
is used by some of the other vendors.
<port_type> <port1>: Specify Port 1’s port type and port number. Port 1 is also known as W port (West port)
which is used by some of the other vendors. When this port is interconnected with the other sub-ring, “0” is used
in this field to indicate that no west port is associated with this instance.
[ interconnect ]: Specify this parameter if this is an interconnected node for this instance.
Show: #
show erps [ <groups> ] [ detail | statistics ]
Содержание MSW-4424C Series
Страница 1: ...1 MSW 4424C MSW 4424CS L2 Gigabit Carrier Ethernet Switch ...
Страница 382: ......