background image

Connectors 

 
 
 
 
 
 

 
 

       Figure 1. Front Panel 

LAN & Fiber Ports 

IFS-803GSM(-E)  switches  have  8  electrical  LAN  ports  (labeled 

1

~

8) and 3 fiber ports (SFP based, labeled 1

~

3) on the front panel. 

The  LAN  ports  that  utilize  shielded  RJ-45  connectors  support 
10/100M; while the fiber SFP ports support 100/1000M. 

CONSOLE Port 

The  RJ-45  port  labeled  “CONSOLE”  is  an  RS-232  terminal  port 

for local management. These models use a “light” CLI (Command 

Line  Interface)  in  addition  to  a  user  friendly  Web  interface  and 

industry  standard  SNMP.  See  page  5  for  basic  CLI  and  Web 

operation. 

One RJ-45 to DB-9 cable is provided with this device. CONSOLE 

port pinouts (Figure 2) and RS-232 DB-9 (Figure 3) connector are 

illustrated  below  together  with  RJ-45  to  DB-9  signal  mapping 

information.  Use  the  supplied  cable  to  connect  the  RJ-45 

CONSOLE port to a console PC. 

 
 
 
 
 
 

Figure 2. CONSOLE Port Pinout 

 
 
 
 
 
 

   Figure 3. RS-232 (Female) Pinout 

 

 

CLI & Web Basic Operation 

IFS-803GSM(-E)  are  managed  Fast  Ethernet  switch  devices. 

Initial  configuration  (assignment  of  IP  address)  may  be 
accomplished via the RS-232 console and a PC or laptop running 
terminal emulation software. Configure the terminal as follows: 

115200 speed 
8 data bits 
no parity 
1 stop bit 
no flow control 

IFS-803GSM(-E)  switches  use  a  command  line  interface  (CLI) 

through the serial port. Once the IP address has been configured, 
a  web  browser  can  be  used  to  configure  the  device  through  a 

more  easy  to  use  GUI  (graphical  user  interface).  Please  refer  to 
the operation manual on the CDROM. 

Using  the  provided  console  cable,  connect  the  RJ-45  to  the 

“CONSOLE” port and the DB9 to PC COM port. Apply power to the 
switch. At the "Username:" prompt, enter '

admin

' (lower case, no 

quotes). Just

 press Enter when prompted for password

To set the IP address and subnet mask issue this command: 

> ip address 1 192.168.0.250/24 
(example: sets VID 1 to 192.168.0.250, subnet 255.255.255.0) 
 

NOTE: The factory default IP address is 10.1.1.1 with mask 
255.255.255.0

 

RJ-45 to DB-9 Signal Mapping 

DB-9 (Female) 

Direction 

RJ-45 

Signal 

Pin 

Pin 

Signal 

RXD 

 

TXD 

TXD 

 

RXD 

GND 

 

GND 

 

 

Power and Alarm 

 
 

 
 
 
 

 
 

Figure 4. Terminal Block 

A  removable  terminal  block  on  the  top  panel  provides  both 

power  and  alarm  connections.  Power  can  be  provided  through 
the  dual  inputs  from  separate  sources.  The  alarm  relay  contact 

can  be  wired  into  an  alarm  circuit  which  senses  an  alarm 
condition when the contact is broken. The alarm relay is normally 
closed when there is no alarm condition. The alarm conditions are 

user  programmable  through  management  to  include  power,  link 
faults  or  other  fault  conditions.  Please  note  that  the  alarm  relay 
contact  can  only  support  1A  current  at  24VDC.  Do  not  apply 

voltage and current that exceed these specifications. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Indicators 

LED 

Color 

Definition 

PWR1/ 

PWR2 

Green 

Power is connected and active at the 
PWR1/PWR2 input terminal 
connection.

 

Off 

PWR1/PWR2 is not connected. 

Fault 

Amber 

When one or more of the 
programmable alarm conditions is 
active.

 

Off 

Normal operation without faults. 
Alarm conditions are all disabled. 

CPU ACT 

Green 

During normal use, this LED will be lit, 
indicating a healthy condition of the 
running CPU. 

Ring 

Master 

Yellow 

Lit when this unit is the 'master' in a 
fiber ring and all units are configured 
for u-Ring or ERPS (Ethernet Ring 
Protection Switching or G.8032). 

LAN 

LINK/ACT 

Green 

The connected LAN speed is 
10/100M.  

Blinking 

Blinking when there is Ethernet 
traffic. 

Off 

No Ethernet link. 

FIBER 

LINK/ACT 

Green 

The fiber link is up.  

Blinking  Blinking when there is data traffic. 

Off 

No fiber link. 

Application 

 

- 3 - 

- 4 - 

- 6 - 

Figure 6. u-Ring Topology and Application 

Fault 

Figure 5. Alarm Relay Circuit 

Normally Closed (NC) 

- 5 - 

www.ctcu.com 