APPENDIX A
u-Ring CONFIGURATION PROCEDURE
367
Verification:
There are three ways to verify the configured settings. The first one is to check link status via Satus
page. Second, using ping to test the connectivity between switches. Finally, disconnect a port to
see whether the blocked port is brought back to “Forwarding” mode or not.
A.
Check the Redundancy>u-Ring>status page of each device.
SW#1
1.
The role of SW#1 is “Slave” which means that East and West port will not be blocked (forward
data).
2.
East and West port are “Forwarding” data.
3.
The “Green” color means that the ring connection is good.
SW#2
1.
SW#2 has the biggest MAC address among switches in the ring. Therefore, it is elected as the
“Master” which means that one of the connected ports will be blocked.