Chapter 4. Web Configuration & Operation
280
CHAPTER 4
WEB OPERATION & CONFIGURATION
General Settings
Enable Loop Protection:
Enable or disable loop protection function.
Transmission Time:
The interval between each loop protection PDU sent on each port. Valid values are 1 to 10
seconds.
Shutdown Time:
The period for which a port will be kept disabled. Valid values are 0 to 604800 seconds. 0 means that
a port is kept disabled until next device restart.
Port Configuration
Port:
List the number of each port. “Port *” settings apply to all ports.
Enable:
Enable or disable the selected ports’ loop protection function.
Action:
When a loop is detected on a port, the loop protection will immediately take appropriate actions. Actions will
be taken include “Shutdown Port”, “Shutdown Port and Log” or “Log Only”.
Shutdown Port:
A loop-detected port is shutdown for a period of time configured in “Shutdown Time”.
Shutdown Port and Log:
A loop-detected port is shutdown for a period of time configured in “Shutdown Time”
and the event is logged.
Log Only:
The event is logged and the port remains enable.
Tx Mode:
Enable or disable a port to actively generate loop protection PDUs or to passively look for looped PDUs.