
132
CHAPTER 3
CLI CONFIGURATION
# show mvr [ vlan <v_vlan_list> | name <mvr_name> ] [ group-database [ interface ( <port_type>
[ <v_port_type_list> ] ) ] [ sfm-information ] ] [ detail ]
3.9.31.10 (config)# mvr vlan <v_vlan_list> frame priority
Syntax:
(config)# mvr vlan <v_vlan_list> frame priority <cos_priority>
Explanation:
Configure
the priority for transmitting IGMP/MLD control frames for the specified MVR VLAN ID.
Parameters:
<v_vlan_list>: Specify MVR VLAN ID for this entry.
<cos_priority>: Specify a Cos priority for this MVR entry. The allowed range is from 0 to 7.
Example:
Set up a MVR VLAN 201 and its corresponding priority value “0”.
Negation
: (config)# no mvr vlan <v_vlan_list> frame priority
Show:
> show mvr [ vlan <v_vlan_list> | name <mvr_name> ] [ group-database [ interface ( <port_type>
[ <v_port_type_list> ] ) ] [ sfm-information ] ] [ detail ]
# show mvr [ vlan <v_vlan_list> | name <mvr_name> ] [ group-database [ interface ( <port_type>
[ <v_port_type_list> ] ) ] [ sfm-information ] ] [ detail ]
3.9.31.11 (config)# mvr vlan <v_vlan_list> frame tagged
Syntax:
(config)# mvr vlan <v_vlan_list> frame tagged
Explanation:
Tagged IGMP/MLD frames will be sent.
Parameters:
<v_vlan_list>: Specify MVR VLAN ID for this entry.
Example:
Set MVR VLAN 201 to send tagged IGMP/MLD frames.
Negation
: (config)# no mvr vlan <v_vlan_list> frame tagged
Show:
> show mvr [ vlan <v_vlan_list> | name <mvr_name> ] [ group-database [ interface ( <port_type>
[ <v_port_type_list> ] ) ] [ sfm-information ] ] [ detail ]
# show mvr [ vlan <v_vlan_list> | name <mvr_name> ] [ group-database [ interface ( <port_type>
[ <v_port_type_list> ] ) ] [ sfm-information ] ] [ detail ]
# config t
(config)# mvr vlan 201 frame tagged
# config t
(config)# mvr vlan 201 frame priority 0
Содержание IFS-1604GSM Series
Страница 385: ......