Installation Instructions for IFC-100PD
(Power Device) 10/100Base-T/TX to
100Base-FX PoE Fiber Media Converters
Description
The IFC-10/100PD gives you an economic solution for media conversion between fiber and copper
Ethernet with its PoE (Power over Ethernet) features, this converter can draw power directly from the
UTP cable. It accepts power from a UTP-based Power Sourcing Equipment (PSE) and supports the
IEEE 802.3af standard. It also gives you the option to choose from the most popular fiber cabling
connectors, ST, SC connectors for your fiber optic cables and RJ-45 port for 10/100Base-TX unshielded
twisted pair cable connection.The factory default settings of Ethernet auto-negotiation and fiber full
duplex may be modified by adjustment of external DIP switches to force Full/Half 10/100 or LFP (Link
Fault Pass-through) function settings. The IFC-100PD gives you the freedom to extend your Ethernet
connection without any external power adapter and offers a versatile solution for media conversion.
You can deploy it just about anywhere with no need to be near a power outlet The maximum extension
of 10/100Mbps cabling distance is up to 120 kilometers over fiber. Six LED indicators signal the power
and PoE status, UTP port speed, Link/Act, duplex status and FX port Link/Act.
V.: 1.0
Specifications
Standard
IEEE802.3 10Base-T, IEEE802.3u 100Base-TX, l00Base-FX, IEEE802.3af PoE PD (Class 3)
Supports Full/Half Duplex Ethernet mode
N-Way Auto Negotiation
10/100Base-TX RJ-45 Connectors
One RJ-45 connector is provided for connection to MDI-X (To PC) or MDI (To HUB) equipment.
Auto MDI-X allows all UTP connections to be made using only a common straight-through UTP cable.
IFC-100PD accepts power from a UTP based power sourcing equipment (PSE) and support the
IEEE802.3af PoE PD (Class 3) standard.
MDI-X type
MDI type
RJ-45 Pin
1
2
3
6
Rx+
Rx -
Tx+
Tx -
Tx+
Rx+
100Base-TX UTP Cable
Cable type: 100Base-Tx; Category 5 or better
Maximum cable distance: 100 meters (328 feet)
Fiber Optic Connectors
For IFC-100PD: Two connectors are provided for fiber optic cable connection.
One is for transmission and the other is for reception of optical data
For IFC-100PD WDM: One connector is provided for fiber optic cable connection.
For both transmission and reception of optical data.
*Please note that transceiver type A must connect to transceiver type B for proper fiber linking.
Environment
Temperature : 0
o
C –50
o
C
Humidity: 5-95% non condensing
Dimension
73.4mm x 108mm x 23mm
( W x D x H )
Power
AC a12V / 400mA
Tx -
Rx -
Fiber
Connections
Ethernet
Connections
DC Jack
LEDs
DIP
Switch
DIP Switch Setting
SW1
SW2
SW3
SW4
DIP
UTP Mode
UTP Speed
UTP Duplex
Link Fault Pass-through
Function
Auto mode.
Manual mode.
100Mbps.
10Mbps.
Full Duplex.
Half duplex.
LFP off.
LFP on.
Status
Off
On
Off
On
Off
On
Off
On
State
Fiber
Media Converter
100PD
100PD