Chapter 2 Provisioning
18
2.2.4 Chassis Information and Alarm setup
The
FRM220A
supports two user configurable alarms for a number of different alarm conditions. Alarm
conditions are configurable for alarms from Power, Fans, and UTP or Fiber link and Far End Fault states for local
and remote converters.
From the System Status and Configuration menu of the FRM220A, press the '4' (four) key to enter the Alarm
Status and Configuration.
CTC UNION TECHNOLOGIES CO., LTD. FRM220A-GSW/SNMP VER.[1.025]
===============================================================================
This Chassis ID:[00] Cascaded:[No ] Monitored Chassis ID:[00]
<< Alarm Status and Configuration >>
Alarm 1 Status [Inactive]
Alarm 2 Status [Inactive]
<1> :Alarm 1 Mode [By Power]
<2> :Alarm 2 Mode [By Fan]
<3> :User Define 1 Configuration.
<4> :User Define 2 Configuration.
<ESC>:Go to Previous Menu.
Description of Menu contents:
This Chassis ID
: This ID number will reflect the actual ID number set on the selector switch on the rear of the chassis
Alarm 1 Status / Alarm 2 Status
: Indicated whether there is currently an active alarm or if no alarm (inactive).
Power#1 and Power#2
Type: & Status
The
FRM220A
can accommodate two power supply modules of any type. There are three types available:
1. AC Model, supports 90~250VAC input, 200watt maximum output.
2. DC48 Model, supports 36-75VDC input, 200 watt maximum output
3. DC24 Model, supports 18~36VDC input, 200 watt maximum output
Fan#1 and Fan#2
RPM & Status
There are two hot swappable cooling fan assemblies that may be field replaced. The normal operational
revolutions per minute (RPM) are between 2800 and 4900. The threshold for fan alarm is activated if the fan's RPM
falls below 800RPM.
Alarm#1.
In the default configuration, Alarm #1 is Active if any failure condition exists for power. Alarm #2 is active if any
fan fails or the RPM falls below the acceptable threshold (800RPM).
For an example of configuration for Alarm #1, press '1' (one).
Set Alarm 1 Mode.
<0> Disable <1> By Power <2> By Define 1 <3> By Define 2
<ESC>:Previous Menu.
0
: This will completely disable Alarm #1.
1
: This is the factory default setting. This alarm will only be off when two power modules are installed and powered on.
2
: This setting will take the user parameters and set the alarm according to failures in parameters set under items 1.
3
: This setting will take the user parameters and set the alarm according to failures in parameters set under items 2.
Содержание FRM220A-GSW/SNMP
Страница 1: ...FRM220A GSW SNMP Gigabit Switch SNMP Controller ...
Страница 2: ......
Страница 6: ...Table of Contents ii ...
Страница 30: ...Chapter 3 Web Based Management 30 This page left blank intentionally ...
Страница 47: ...Appendix A 47 ...
Страница 50: ......
Страница 51: ......
Страница 52: ......