CTC Union FRM220-100M Скачать руководство пользователя страница 1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

USER MANUAL 

 

FRM220-100M(S) 

Fast Ethernet OAM/IP 
Web Smart Media Converter 

 
 

Содержание FRM220-100M

Страница 1: ...USER MANUAL FRM220 100M S Fast Ethernet OAM IP Web Smart Media Converter...

Страница 2: ......

Страница 3: ...M S Operation Manual Fast Ethernet OAM IP Web Smart Media Converter Version 1 0 December 5 2011 First Release Version 1 01 March 14 2012 update This Manual supports the following models FRM220 100M 1x...

Страница 4: ...ury or death that may be associated with such unintended alleges that CTC Union Technologies was negligent regarding the design or manufacture of said product TRADEMARKS Microsoft is a registered trad...

Страница 5: ...ALLATION OF SFP MODULES 2 3 1 Inserting a Bale Clasp SFP Module into the Cage 2 3 2 Removing a Bale Clasp SFP Module CHAPTER 3 PROVISIONING 3 1 CONSOLE LOGIN 3 1 0 Console Main Menu 3 1 1 UTP Configur...

Страница 6: ...3 2 4 System Information Network Information 3 2 5 System Information DD Information 3 2 6 Local Settings 3 2 7 Remote Settings 3 2 8 802 3ah OAM Functions 3 2 9 Tools 3 2 10 Logout 3 3 TROUBLESHOOTI...

Страница 7: ...Based Management and Trouble Shooting to become familiar with the diagnostic capabilities strategies for both stand alone or within the SNMP managed chassis 1 2 Product Description FRM220 100M is an...

Страница 8: ...ation for management Includes RMON counters stand alone only Supports password setting for authentication Supports Link Fault Pass Through LFP Function Supports Auto Laser Shutdown ALS Function Suppor...

Страница 9: ...k LAN Speed Power Card supports hot swapping Input Card 12VDC Standalone AC DC options Consumption 4W Dimensions 155 x 88 x 23mm D x W x H Weight 110g Temperature 0 60 C Operating 10 70 C Storage Humi...

Страница 10: ...seconds to fully boot Using a pencil or ball point pen press the DEFAULT recessed push button switch located on the face plate and hold for 6 seconds The unit will be restored to factory default almo...

Страница 11: ...ssis Chassis with built in power are a single DC 18 75VDC dual AC dual DC or AC plus DC combo The single slot chassis with external voltage only with the provided 90 240VAC 12VDC 400mA switching adapt...

Страница 12: ...round DC IN Left V 48V 2 3 Installation of SFP Modules CTC Union supplied SFP modules are of the Bale Clasp type The bale clasp pluggable module has into the SFP cage 2 3 1 Inserting a Bale Clasp SFP...

Страница 13: ...ager Model FRM220 100MS Ver 1 000 1 000 0 000 0 000 CH 01M Local User Name admin Password 3 1 0 Console Main Menu CTC UNION TECHNOLOGIES CO LTD FRM220 100M Manager Ver 1 00 Model FRM220 100M Ver 1 000...

Страница 14: ...ted When an 802 auto negotiation mode failure to negotiate Duplex for example if connected to legacy equipment or to will result in the Auto device assuming a Half Duplex operating mode Do not connect...

Страница 15: ...abled all transmission through this port wil be extinguished however any connected device will still detect a fiber link When the fiber Management option is disabled all management communication with...

Страница 16: ...ser Shutdown is a safety mechanism that will disable laser output when no received optica disabled Link Fault Pass Through or LFP is a method of forwarding a link loss from copper to fiber or from fi...

Страница 17: ...we can remote manage another fiber con addressing From this menu we can also perform some basic diagnostics such as loop back test To use the OAM functions the 802 3ah Active setting must be enabled...

Страница 18: ...s the copper fiber and CPU manage Type The following operations may be performed to the outgoing frames 1 Replace Tag The switch then add new tags to them The inserted tag is defined in VLAN Group Ind...

Страница 19: ...ex Number 0 6 CPU VLAN Group Index Number 1 7 VLAN Ingress Filter Enable 8 VLAN Group Enable 9 VLAN Group Table Status TP mem FX mem CPU mem PVID 0 VLAN Table 0 V V 1 1 VLAN Table 1 V 555 2 VLAN Table...

Страница 20: ...unction Q in Q Tag Priority provid Internal priority the three bit VLAN tag priority bits are mapped to the internal 2 bit priority When selec will be used instead Q in Q Direction sets up how the tag...

Страница 21: ...ress is the dotted decimal format for the IPv4 address to remotely manage this device The Subnet Mask defines the type of subnet the device will be on The proper subnet setting will be d The Gateway i...

Страница 22: ...frame network which currently only exists in data cen storage connections and on some back bone networks Jumbo frames will always be considered to be i according to IEEE802 3 In most cases the call fo...

Страница 23: ...on the network or an Ethernet transc addition there are the deliberate attempts to bring a network down through virus and denial of service ro Storm Filter will recognize and block the forwarding of t...

Страница 24: ...d Password Please Keyin New Password Please Keyin Cfm Password The password setting protects FRM220 100M against unauthorized access to the management from the password select p from the main menu nex...

Страница 25: ...1 1 1 Before accessing this device by web browser the IP address must be known or it must be reset o network Please refer to Chapter 1 section 1 6 or to Chapter 2 section 3 1 9 for the factory reset p...

Страница 26: ...3 2 3 Web Main Page 26...

Страница 27: ...System Information Network Information The information displayed on this page gives specific device network information and port status fo remote that is accessible via IEEE802 3ah OAM in band managem...

Страница 28: ...from the MSA compliant SFP module and can be displayed via 3 2 6 Local Settings If you have reviewed section 3 1 of this chapter then you will already be familiar with these settings the settings here...

Страница 29: ...IP configuration for the local unit Note that if you change the management for this device Remember to save settings under the Tools menu 3 2 6 2 Password Setting Key in the current password and type...

Страница 30: ...3 2 6 3 Converter Configuration All of these special functions are explained in Section 3 1 8 of this chapter Select the proper radio bu Remember to save settings under the Tools menu 30...

Страница 31: ...X The the port setting auto or forced Ethernet mode enabling 802 3X and setting ingress and egress rate granularity of 64K so the rate can be set from 64k to 100M in 64K steps 3 2 6 5 Q in Q Configura...

Страница 32: ...3 2 6 6 RMON Counters The counters have an accumulation of received bytes for each port UTP Fiber and Management a packets 32...

Страница 33: ...3 2 6 7 VLAN Group Configuration FRM220 100M supports up to 16 VLAN groups By using the check boxes for each port the access to di 33...

Страница 34: ...received without tags 3 Add Tag The switch will not tagged when these packets are output on this port The switch will not add tags to packets already VLAN Group Index 4 Don t Touch Tag Do not insert...

Страница 35: ...3ah OAM Functions This converter supports IEEE 802 3ah an OAM protocol that operates at Ethernet Layer 2 Data Link monitor link operation health and to improve fault isolation OAM only works point to...

Страница 36: ...her must be passive We typicall passive mode and make the local converter active Passive is the default setting when 802 3ah functio In order to do Remote Loop Back test the option must be enabled in...

Страница 37: ...ntrols the packet size of the OAM frames used for loop The CRC of Ethernet packets uses 4 bytes Valid Ethernet packets range in size from 64 bytes to 1518 for a maximum size of 1522 bytes Q in Q adds...

Страница 38: ...the state of OAM if OAM is enabled We can also see the MAC ad in the OAM manageable pair The Flags Field list the results of individual events based on the OAMPDUs Lastly when two OAM devices start ne...

Страница 39: ...atio the information This display has TLV information for both the local and remote OAM units Ethernet OAM also defines a set of standard event conditions that Ethernet links should monitor should be...

Страница 40: ...an equipment or facility failure Dying gasp provides this information by having a station ind power failure If remote management is lost we simply need to check the Remote Dying Gasp Count register to...

Страница 41: ...out rebooting The converter requires about 20 25 seconds to fully reboot 3 2 9 2 Save and Restore After performing configuration of the converter the settings must be saved Click the Save To Flas to a...

Страница 42: ...owser Post it is checked for integrity the flash is erased and then the flash is written with the DO NOT LET ANY POWER INTERRUPTION OCCUR DURING THE UPGRADE PRO Click the Browse button and locate the...

Страница 43: ...oubleshooting 3 3 1 Factory Default Apply power to FRM220 100M and allow 25 30 seconds to fully boot Using a pencil or ball point push button switch located on the face plate and hold for 6 seconds or...

Страница 44: ...3 3 2 3 Fiber Link Test Following a complete power and boot up about 25 seconds the converter will be active For FRM2 module into Fiber Port cage Use a simplex patch cable single fiber strand LC to L...

Страница 45: ...u switch to another FRM220 100M be sure to clear the has the same default IP address but every unit has a different MAC address To clear the PC s MAC execute the command arp d In addition if you disco...

Страница 46: ......

Отзывы: