Installation of DualCom UDL to
Texecom Premier and Elite
CSL262V8 14042016
DualCom Setup
Place the Texecom panel in engineer mode
Connect the aerial provided to the DualCom
Connect the DualCom directly to the COM 2400 board via the “to panel digi” port on
the DualCom
The DualCom will go through its power up/registration process which will take
approximately 2-3 minutes
The top “SVC” LED will start to pulse like a heartbeat once locked onto the network
The signal strength will then be displayed
Leave the DualCom to conduct an internal network survey – this will happen
automatically. The display will show 0.0, 0.1, 0.2, etc
Once the survey is complete you then need to proceed to panel programming
If triggered inputs on the DualCom are being utilised in fast format then proceed to
“Panel Programming (UDL)”
Panel Programming (SIA)
Enter engineering menu
Press down arrow until you reach “UDL/Digi Options”, then press YES
Press down arrow until you reach “Program Digi”, then press YES
Display shows “ARC 1 Protocol Disabled”. Press NO and then down arrow until “SIA
Level II” is displayed
Press YES, then YES again, display shows “Primary No”. Press NO and enter number 01
followed by YES
Press down arrow once to “Secondary No”, then press NO and enter number 01
followed by YES
Press YES until “Account Number” is displayed, press NO then enter the DualCom’s chip
number followed by YES
Press down arrow to “Config (* * * * * * * *)” press NO then down arrow until Send SIA
Text is displayed, press No and display will now show “Send SIA Text (* * * * * * * T)”
press YES
Press menu then down arrow until “Digi Options” is displayed, press YES
“Digi Options (* * * * * *)” is displayed, press NO twice
Display will now show “Digi is Enabled (E * * * * *)” press YES
Unit is now setup to send SIA to the ARC via the dial capture ports