Fiberlink®

8200 Series

3G/HD/SD-SDI Optical/Copper Hybrid  

Optical Distribution Amplifiers 

Communications Specialties’ Fiberlink® 8200

User’s Manual

The Fiberlink® 8200 Series of 

optical distribution amplifiers 

accept a 3G/HD/SD-SDI or  

DVB-ASI signal via BNC or its 

optical input and outputs 

it on one, two, three or four 

independently driven optical 

fibers

Содержание Fiberlink 8200 Series

Страница 1: ...on Black Backgrou Fiberlink 8200 Series 3G HD SD SDI Optical Copper Hybrid Optical Distribution Amplifiers Communications Specialties Fiberlink 8200 User s Manual The Fiberlink 8200 Series of optical...

Страница 2: ...ackage Contents 3 Technical Specifications 4 Alarm Switch Settings 6 Part Numbers Wavelength Identification 6 Installation Instructions 7 Indicator LEDs 8 Operating Pointers 9 Troubleshooting 9 Mainte...

Страница 3: ...se with CWDM multiplexers such as CSI s 6400 CWDM Series and the Fiberlink FlexPOD Features Switch selectable copper or optical 3G HD SD SDI input Supports 3G HD SD SDI and DVB ASI signals Available w...

Страница 4: ...3360 3380 2302 4 3353 3355 and other SMPTE compliant devices Serial Video BNC Input Number of Inputs 1 Date Rate Range 19 4 Mbps to 2 97 Gbps Supported Standards SMPTE 259M 292 297 2006 424M 2006 305M...

Страница 5: ...ershoot 10 of amplitude Timing Jitter 0 2 UI at 270 Mbps 1 0 UI at 1 485 Gbps 2 0 at 2 97 Gbps with color bar signal Alignment Jitter 0 2 UI at 270 Mbps 0 2 UI at 1 485 Gbps 0 3 at 2 97 Gbps with colo...

Страница 6: ...30 H 1450 I 1470 J 1490 K 1510 L 1530 M 1550 N 1570 O 1590 P 1610 Alarm Switch Settings for the 8200 Series Card Switch Position Alarm Indication On Off 1 Loss of BNC Input Video Enabled Disabled or O...

Страница 7: ...active re clocked loop through signal of the input selected by the switch is available on the BNC Loop Through connector 6 When a valid SDI input signal is detected on the input selected by the front...

Страница 8: ...icates no HD SDI data rate lock On Indicates HD SDI data rate lock at 1 485 Gbps or 1 485 1 001 Gbps SD Rate Off Indicates no SD SDI or DVB ASI data rate lock On Indicates SD SDI or DVB ASI data rate...

Страница 9: ...lure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output signal connections are correct An optical power meter such as the...

Страница 10: ...light transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the Fiberlink...

Страница 11: ...ed at its option to either the repair or replacement of defective units including free materials and labor In no event shall CSI be responsible for any incidental or consequential damages or loss of p...

Страница 12: ...Power Meter measures the power of optical signals at 850 980 1310 and 1550 nm wavelengths allowing for convenient on site testing of fiber networks during construction and maintenance procedures It ca...

Страница 13: ...Page 13 Fiberlink 8200 Series User s Manual Fiberlink 8200 Series...

Страница 14: ...Page 14 Fiberlink 8200 Series User s Manual Fiberlink 8200 Series...

Страница 15: ...Page 15 Fiberlink 8200 Series User s Manual Fiberlink 8200 Series...

Страница 16: ...d Fiberlink and the starburst logo are registered trademarks of Communications Specialties Inc CSI and the triangle designs are trademarks of Communications Specialties Inc P N 129226 Rev B Fiberlink...

Отзывы: