48
CSI Readers
Specifications
Installation Guide
PR-505
Power and Environment
Power:
5 to 12 VDC at 45 mA (linear power supply
required)
Operating Temperature: –22
°
to 149
°
F (–30
°
to +65
°
C)
Cable:
350 feet (100 m) 24 AWG (0.206 mm
2
) shielded,
6-conductor stranded (Belden 9536) or 7-conductor stranded
(Belden 9537)
Output
Signal
:
26/32-bit Wiegand data format.
Dimensions:
4.60" L
×
3.90" W
×
0.50" D
(11.7
×
7.4
×
1.3 cm)
Indala ARE-142
Power and Environment
Power:
12 VDC
±
15% at 0.9 A (linear power supply
required)
Operating Temperature:
32
°
to 122
°
F (0
°
to 50
°
C)
Cable Length from ARE-142 to Host Controller:
With PR103 & -105: 500 feet (150 m) 24 AWG
(0.206 mm
2
) shielded, 6-conductor stranded (Belden
9536) or 7-conductor stranded (Belden 9537)
With PR-120 & -122:
350 feet(100 m) 24 AWG
(0.206 mm
2
) shielded, 6-conductor stranded (Belden
9536) or 7-conductor stranded (Belden 9537)
Weight:
9.9 oz. (280 g)
Output
Signal
:
26/32-bit Wiegand data format.
Dimensions
:
4.6" L
×
5.5" W
×
3.5" D
(11.7
×
14.0
×
8.9 cm)
Hughes ProxPro
Power and Environment
Power:
10–28.5 VDC at 100 mA (160 mA peak)
(linear power supply required)
Operating Temperature:
–22
°
to 150
°
F (–30
°
to 65
°
C)
Cable:
500 feet (150 m) 22 AWG (0.324 mm
2
) shielded,
6-conductor stranded.
Weight:
12 oz. (336 g)
Output
Signal
:
26/32-bit Wiegand data format.
Dimensions
:
5.0" L
×
5.0" W
×
1.0" D
(12.7
×
12.7
×
2.54 cm)
ESSEX PIN Pad
Power and Environment
Power:
12 VDC
Operating Temperature:
–40
°
to 160
°
F (–40
°
to 71
°
C)
Output
Signal
:
26/32-bit Wiegand data format.
Motorola/Indala ARK-501
Power and Environment
Power:
5–14 VDC (linear power supply required)
Current:
50 mA at 14 VDC
Operating Temperature:
–22
°
to 149
°
F (–30
°
to 65
°
C)
Cable:
500 feet (150 m) 24 AWG (0.206 mm
2
) shielded, 6-
or 7-conductor stranded.
Weight:
11.9 oz. (337 g)
Output
Signal
:
26-bit Wiegand data format.
Dimensions
:
4.55" L
×
3.00" W
×
0.65" D
(11.56
×
7.60
×
1.65 cm)
Dorado 780
Power and Environment
Power:
8–12 VDC
Operating Temperature:
–31
°
to 150
°
F (–35
°
to 66
°
C)
Cable:
500 feet (150 m) 22 AWG (0.324 mm
2
) shielded,
6-conductor stranded.
Output
Signal
:
26-bit Wiegand data format.
Dimensions
:
6.75"L
×
5.25"W
×
2.75"D
(17.15
×
13.34
×
6.99 cm)