background image

Application area 

DP 400 mobil  V1.00 EN 

Seite 5 von 15 

2  Application area 

The portable dew point measuring device in a robust case has been specially developed for field 
applications. The device has a high-precision digital dew point sensor. In addition to the dew point 
(pressure dew point), the temperature, relative humidity, absolute humidity (g / m³) as well as other 
moisture values are measured. Integrated pressure measurement up to 16 bar. 

The measuring gas / compressed air is connected via PTFE hose to the 6mm plug connections. 

The operation is carried out via the clear 3.5 "touch screen. The optional data logger enables the 
recording of all measured values over hours, days or weeks (100 million measured values of storage 
capacity) 

Any analogue sensors (0/4 - 20 mA, 0 - 1/10/30 V), pulse) are easy and fast to configure. Digital 
sensors can be connected via RS 485, Modbus RTU. 

Optional: 

Network-capable and data transmission worldwide via Ethernet, integrated web server. 

3  Intended use 

The  dew  point  measuring  device  with  data  logger  DP  400  mobile  is  designed  for  portable  data 
acquisition and storage of analog and digital input signals. 

The DP 400 mobil is designed and designed exclusively for the intended use as described herein and 
may only be used accordingly. 

The user must check whether the device is suitable for the selected application. Ensure that the medium 
is compatible with the media-bearing parts. The technical data in the data sheet are binding. 

Incorrect handling or operation outside the technical specifications is prohibited. Claims of any kind due 
to improper use are excluded. 

Содержание DP 400 mobil

Страница 1: ...DP 400 mobil V1 00 EN Seite 1 von 15 Installation and operating instructions portable dew point meter with integrated pressure measurement DP 400 mobil EN English...

Страница 2: ...vour of the DP 400 mobil Please read this installation and operation manual carefully before mounting and initiating the device and follow our advice A riskless operation and a correct functioning of...

Страница 3: ...nsors 7 6 Cable cross section 7 6 1 Sensor circuit points Output signal 7 7 Installation Connection Measurement 8 7 1 User controls connection 8 7 1 1 Dew point measurement 8 7 1 2 Display Datalogger...

Страница 4: ...ons e g VDE 0100 Carry out maintenance only in strain less state All electric works are only allowed to be carried out by authorized qualified personnel Warning Inadmissible operating parameters Under...

Страница 5: ...the Dangerous Goods Legislation requirements The user can transport the batteries by road without further requirements When being transported by third parties e g air transport or forwarding agency s...

Страница 6: ...measured values of storage capacity Any analogue sensors 0 4 20 mA 0 1 10 30 V pulse are easy and fast to configure Digital sensors can be connected via RS 485 Modbus RTU Optional Network capable and...

Страница 7: ...point 1 C for 20 20 Ctd 2 C for 20 50 Ctd 3 C for 50 80 Ctd Accuray pressure 0 5 Power supply for sensors Output voltage 24 VDC 10 Output current a Digital board 120 mA continuous operation b Analogu...

Страница 8: ...y 0 03 mA 0 05 Input resistance 50 Voltage signal 0 1V Measuring range 0 1 V Resolution 0 05 mV Accuracy 0 2 mV 0 05 Input resistance 100 k Voltage signal 0 10 V 30 V Measuring range 0 10 V 30 V Resol...

Страница 9: ...0 EN Seite 8 von 15 7 Installation Connection Measurement 7 1 User controls connection 7 1 1 Dew point measurement Plug in connection Medium closed with red seal plug Medium output Control Medium on o...

Страница 10: ...ob during operation opens a popup with indication of the remaining operation time The data logger is operated via the touchpanel integrated in the display 7 1 3 Sensor connections Power supply connect...

Страница 11: ...vice is compromised Before disconnecting the DP 400 mobile from the gas line it is necessary to vent the system to atmospheric pressure otherwise serious injuries may occur Note At delivery the dew po...

Страница 12: ...ng point should be as close as possible to the critical measuring point in order to obtain a truly representative measurement The length of the DP 400 mobile cable should be as short as possible Only...

Страница 13: ...ld be activated between the measurements or especially during longer periods of interruption and storage This is to protect the moisture sensor from excessively high moisture and thus to ensure fast r...

Страница 14: ...sharp edges The foil can be damaged The DP 400 mobile is pre configured i e the pressure dew point temperature pressure as well as rel humidity are displayed directly on the start screen Configuratio...

Страница 15: ...oap For decontamination spray the cleaner on an unused cotton cloth or one way wipe and wipe the component comprehensively Perform the final drying with a clean cloth or by air drying In addition the...

Отзывы: