CS4281 Programming Manual
68
DS308PRM1
The next register, at configuration space offset 0x42, describes the CS4281’s power management capabil-
ities:
9.3.5
Power Management Capabilities (PMC)
Address:
PCI CFG: 42h, Read-Only
BA0: 342h, Read-Only
Default:
7E22h
Definition: Core powered. This register holds power management capabilities information.
Bit Descriptions:
V[2:0]
Version: The value 2 indicates compliance with version 1.1 of the PCI Bus Power
Management Interface Specification.
PMEC
PME Clock: Set to 0 to indicate the PCI bus clock can be stopped for the CS4281 to generate
PME#
.
VAC[2:0]
Vaux Current. These bits are set from
IISR.VAC[2:0]
which must be initialized by the BIOS to
indicate how much current Vaux pulls. Note this is total current and is the combined CS4281
and any attached Codecs and external logic using Vaux.
000 - 0 mA (self powered/don’t support Vaux)
001 - 55 mA
010 - 100 mA
011 - 160 mA
100 - 220 mA
101 - 270 mA
110 - 320 mA
111 - 375 mA (spec maximum)
DSI
Device Specific Initialization: Set to 1 to indicate the CS4281 needs to be programmed to be
useful. Note that Microsoft operating systems don’t use this bit.
AUXP
Auxiliary Power. This bit is set from
IISR.AUXP
. Not sure what this bit does yet.
D1S
D1 Support: Set to 1 to indicate the CS4281 supports the D1 power management device state.
D2S
D2 Support: Set to 1 to indicate the CS4281 supports the D2 power management device state.
PMD0
PME# Support: Set to 1. CS4281 can generate
PME#
from D0 power state.
PMD1
PME# Support: Set to 1. CS4281 can generate
PME#
from D1 power state.
PMD2
PME# Support: Set to 1. CS4281 can generate
PME#
from D2 power state.
PMD3H
PME# Support: Set to 1. CS4281 can generate
PME#
from D3
hot
power state.
PMD3C
PME# Support: BIOS settable through
IISR.VAUXS
. When set, the CS4281 can generate
PME#
from D3
cold
power state. Note that
VAUX
must be powered in the D3
cold
state for this
bit to be true.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PMD3C
PMD3H
PMD2
PMD1
PMD0
D2S
D1S
VAC2
VAC1
VAC0
DSI
AUXP
PMEC
V2
V1
V0
D
ra
ft
Содержание CS4281
Страница 8: ...Confidential Draft 3 7 00 CS4281 Programming Manual 8 DS308PRM1 D r a f t...
Страница 12: ...Confidential Draft 3 7 00 CS4281 Programming Manual 12 DS308PRM1 D r a f t...
Страница 24: ...Confidential Draft 3 7 00 CS4281 Programming Manual 24 DS308PRM1 D r a f t...
Страница 34: ...Confidential Draft 3 7 00 CS4281 Programming Manual 34 DS308PRM1 D r a f t...
Страница 44: ...Confidential Draft 3 7 00 CS4281 Programming Manual 44 DS308PRM1 D r a f t...
Страница 114: ...Confidential Draft 3 7 00 CS4281 Programming Manual 114 DS308PRM1 D r a f t...
Страница 192: ...Confidential Draft 3 7 00 CS4281 Programming Manual 192 DS308PRM1 D r a f t...