
Crystal Vision
General Purpose Interface
Indigo DT desk top box GPI connections
GPI lines ‘a’ to ‘f’ of each card connect to two rear remote connectors as follows:
Slot no. ‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (1)
9 (1)
18 (1)
26 (1)
19 (2)
20 (2)
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
Table shows pin number (remote number)
Note:
Remote 1: 26-way high-density D-Type female socket. Frame ground is pin 2 and
+5V @500mA is pin 1.
Remote 2: 26-way high-density D-Type male plugs and frame ground is pin 6 and
+5V @500mA is pin 15.
Note: The +5V output is protected by self-resetting thermal fuses, which limit the
total output current available from Remotes 1-2 to approximately 1A.
ViViD 3G User Manual R1.4
15
19 January 2021