background image

10

ENG

SUBWOOFER CONNECTIONS

- The total loudspeaker impedance should not be lower than 1 ohm.
- Never connect loudspeaker cables with the ground of the chassis or the +12 V supply voltage.

If the amplifier is operated with a too low impedance or incorrectly used, the entire sound system
may be damaged. This means a warranty void in such cases.

SIGNAL OUTPUTS TO CONNECT ADDITIONAL AMPLIFIERS

The stereo signal connected to LINE INPUT (Fig. 1,3) will be routed in summed to the output jack OUT
(Fig. 1, 2b). This connection is suited to drive another identical GPX2000.1D amplfier at its input jack
(Fig. 1, 2b). Please check for this mode the section ”Master/Slave Operation” on the bottom of this
page.

OPERATING ELEMENTS

The input sensitivity can be adjusted to any headunit. Turn the volume control of your headunit to the
center medium position and then adjust the input level controls (Fig. 1,5) until you have an average
medium level. This setting usually provides sufficient power reserves at optimum weighted noise voltage.

INPUT SENSITIVITY

The subsonic filter is suited to filter the lower frequencies out from the audio signal to avoid unwanted
hum noises from the subwoofer. Set the desired crossover frequency of the subsonic filter by using
the controller (Fig. 1, 7). Thus to that only the frequencies above the chosen crossover frequency will
be amplified and the subwoofer plays more precised and efficient.

VARIABLE SUBSONIC FILTER

Set the desired crossover frequency of the low pass filter by using the controller (Fig. 1, 6). Thus to
that only the frequencies below the chosen crossover frequency will be amplified and the subwoofer
plays more precised and efficient.

VARIABLE LOWPASS FILTER

By using the bass boost controller (Fig.1, 9) you are able to increase the bass boost level from 0 dB to
12 dB. Use the frequency controller (Fig. 1,8) to set the desired frequency for the bass boost level. The
frequency range goes from 30 Hz to 80 Hz.

Caution:

 Please use the bass boost with care. A too high bass boost may result in serious damages

on the subwoofer.

VARIABLE BASS BOOST WITH VARIABLE FREQUENCY CONTROLLER

The Master/Slave Operation allows to link two identical GPX2000.1D amplifiers. This means you can
connect the in- and outputs of both amplifiers (Fig. 1, 2a and 2b) by a RCA patch cord. Amplifier 1
(Master) sends a summed mono signal to amplifier 2 (Slave). The advantage of this function is, that
the crossover section of amplifier 2 will be bypassed and for both amplifiers the same crossover settings
come into operation, which can be adjusted on the amplifier 1. Then both amplifiers work together as
one big monoblock.

Please observe therefor the section ”MASTER/SLAVE OPERATION (Fig. 5) WITH 2 GPX2000.1D on
page 12 and the figure 5 on the very last page.

MASTER/SLAVE OPERATION

Содержание groundpounder GPX2000.1D

Страница 1: ...MONO VERST RKER MONO AMPLIFIER AMPLIFICATEUR MONO AMPLIFICATORE MONO AMPLIFICADOR DE MONO BEDIENUNGSANLEITUNG USER S MANUAL MODE D EMPLOI MANUALE D USO MANUAL DE USO G PX2000 1D...

Страница 2: ...TA ESP 3 8 13 18 23 ABBILDUNGEN FIGURES FIGURES FIGURI FIGURES 28 BEDIENUNGSANLEITUNG USER S MANUAL MODE D EMPLOI MANUALE D USO MANUAL DE USO INHALTSVERZEICHNIS TABLE OF CONTENT TABLE DES MATI RES SOM...

Страница 3: ...6 mm Technische nderungen vorbehalten 3 DEU GARANTIE Dieses Produkt erf llt die aktuellen EU Mindestgew hrleistungsstandards sofern es in L ndern der Europ ischen Gemeinschaft erworben wurde Um Ihren...

Страница 4: ...ssen des Verst rkers ist ein Kabelquerschnitt von mind 16 mm2 zu verwenden Stellen Sie zun chst eine Verbindung zwischen dem GND Anschluss des Verst rkers und einem geeigneten Masse Anschlusspunkt an...

Страница 5: ...r Slave Betrieb auf dieser Seite unten Mit dem Bass Boost Regler Abb 1 9 k nnen Sie die gew nschte Anhebung des Basspegels einstellen Der Regelbereich liegt zwischen 0 dB und 12 dB Am Regler Abb 1 8 k...

Страница 6: ...zw eine zu geringe Impedanz an den Lautsprecher anschl ssen anliegt Wenn dies eintritt schaltet die integrierte Schutzschaltung den Verst rker automatisch aus und sollte nach Behebung des Problems wie...

Страница 7: ...den Verst rker ein und ausschalten 2 Ist das Ger usch eliminiert die Einschaltleitung des Verst rkers mit einem Verz gerungseinschaltmodul am Steuerer t anschlie en ODER 1 Eine andere 12 V Quelle f r...

Страница 8: ...kOhms 40 180 Hz 12 dB Octave 10 50 Hz 12 dB Octave 0 12 dB 30 80 Hz 30 80 Hz 12 V 9 15 V negative ground 50 A ANL external protection 254 x 46 x 326 mm WARRANTY This product meets the current EU mini...

Страница 9: ...sufficiently specified A cable crosssection of at least 16 mm2 must be used to connect the battery to the amplifier s terminals First connect the GND terminal of the amplifier to an appropriate ground...

Страница 10: ...quencies above the chosen crossover frequency will be amplified and the subwoofer plays more precised and efficient VARIABLE SUBSONIC FILTER Set the desired crossover frequency of the low pass filter...

Страница 11: ...esp a too low impedance load is connected to the speaker outputs If this events the internal built in protection circuit shuts down the amplifier automatically The amplifier should work again properly...

Страница 12: ...turn on module OR 1 Use a different 12 Volt source for REMOTE lead of amplifier i e battery direct 2 If the noise is eliminated use a relay to isolate the amplifier from noisy turn on output Procedure...

Отзывы: