4.4. Performance Characteristics
Table 7: CruizCore
®
XG1350 performance characteristics.
PARAMETER
VALUE
UNIT
Min.
Typ.
Max.
BANDWIDTH
RATE
10
50
Hz
WARM-UP TIME
FAST WARM-UP
0.5
sec
FULL ALIGNMENT
1
5
min
ANGULAR RATE
CONTINUOUS*
100
deg/sec
INSTANTANEOUS
2
150
deg/sec
RESOLUTION
0.01
deg/sec
SCALE FACTOR
ERROR
0.5
1
%
BIAS DRIFT
< 10
50
deg/hr
ACCELERATION
MEASUREMENT
RANGE
2
G
DATA RATE
ADJUSTABLE
3
100
Hz
* The system must be installed in the correct position.
1. Full alignment: The total time that takes for full bias error calibration and temperature compensation. It is the worst
case on condition that the temperature goes up suddenly without temperature compensation.
2. Prolonged time in this condition will introduce heading errors