background image

Crown International
P.O. Box 1000
Elkhart, IN 46515-1000
TEL: 574-294-8200
FAX: 574-294-8FAX
www.crownaudio.com

 Xs500

8/06                                                         135179-1C    

Specifi cations subject to change without prior notice. Latest 
information available at www.crownaudio.com. 
Crown and Crown Audio are registered trademarks of 
Crown International. 
Printed in U.S.A.

© 2006 Crown Audio®, Inc.

Architectural & Engineering Specifi cations

X s   S E R I E S

Xs500 (120 V, 60 Hz model)

The Crown

®

 Xs500 power amplifi er shall be a solid-state two-channel 

model employing Class B output circuitry.

The amplifi er shall include protection from shorted, open and mismatched 
loads, general overheating, DC, high-frequency overloads, under/over volt-
age, and internal faults.

The front-panel controls shall be a power switch and a gray rotary level 
control (one per channel).

The recommended load impedance shall be 2 to 8 ohms.

Rear-mounted input connectors shall be a 3-pin Phoenix-style connector 
(one per channel) and an XLR-1/4" combo connector (one per chan-
nel) including a 3-pin female XLR connector and TRS 1/4" phone jack. 
Rear-mounted output connectors shall be binding posts (one pair per 
channel),  a 4-pole Speakon connector (one per channel), and a 3-pin male 
XLR connector (one per channel) in parallel with the XLR-1/4" combo and 
Phoenix-style input connectors for daisy-chain connections. 

Front panel indicators shall include a yellow Bridge-Mode Indicator that 
illuminates when the Mode Switch is set to the “Bridge” position, a green 
Signal Indicator (one per channel) that illuminates when the channel’s input 
signal level is above –40 dBu, a red Clip Indicator (one per channel) that 
illuminates when the channel’s output signal is being overdriven, a red 
Temp Indicator (one per channel) that illuminates when channel(s) are 
in thermal protect mode, a red Fault Indicator that illuminates when the 
amplifi er is in protect mode and also briefl y during normal power-up when 
amplifi er is fi rst switched on, a yellow Power Indicator that indicates ampli-
fi er has been turned on, and a red AC Mains Indicator that illuminates when 
AC power is present at the power cord.

The power amplifi er shall meet or exceed the following performance crite-
ria. Input sensitivity for rated output: 1.4V. Rated output with both channels 
driven in Dual mode into 8 ohms (1 kHz): 400 watts per channel at 0.15% 
THD. Rated output with both channels driven in Dual mode into 4 ohms: 
500 watts per channel at 0.15% THD. Rated output with both channels 
driven in Dual mode into 2 ohms (1 kHz): 750 watts per channel at 0.5% 
THD. Bridge-mono output power into 8 ohms (1 kHz): 1,450 watts at 
0.15% THD. Bridge-mono output power into 4 ohms (1 kHz): 1,600 watts 
at 0.5% THD. Frequency Response at 1 watt, 22 Hz to 22 kHz: ± 1 dB. 
Signal to Noise Ratio below rated power: > 102 dB A-weighted. Total 
Harmonic Distortion at full rated power from 20 Hz to 20 kHz: < 0.5%. 
Damping Factor: > 200 from 10 to 400 Hz. Crosstalk (below rated power): 
> 55 dB at 1 kHz and 20 kHz. DC Output Offset (shorted input): < ± 75 mV. 
Input Impedance (nominal): 20 kilohms balanced, 10 kilohms unbalanced. 

The amplifi er chassis shall be constructed of steel with a durable black 
fi nish and shall be designed for forced-air ventilation from the front panel 
to the back panel. 

The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA 
standard (RS-310-B) rack mounting. The amplifi er shall be 3.5 inches 
(8.9 cm) tall, and 17.14 inches (43.5 cm) deep behind the rack-mounting 
surface.

The amplifi er shall weigh 28 lb 14 oz (13.1 kg).

The amplifi er shall be designated the Crown Xs500.