Crown IQ-RPT 3 Скачать руководство пользователя страница 1

Crown International

P.O. Box 1000

Elkhart, IN 46515-1000

TEL: 219-294-8200

FAX: 219-294-8FAX

www.crownaudio.com

IQ-RPT 3

9/01                                                              133799-1  

 

Specifications subject to change without prior notice. Latest 

information available at www.crownaudio.com.
© 2001 Crown Audio, Inc. Crown, IQ and IQ System 

are registered trademarks of Crown International. Other 

trademarks are the property of their respective owners. 

Printed in U.S.A.

Architectural & Engineering Specifications

  R E P E A T E R

PRELIMINAR

Y

IQ-RPT 3

The audio system shall utilize a separate component dedicated specifically 

to prevent IQ loop signal degradation by reconstructing the incoming data 

signal and repeating the reconstructed signal out to the next component on 

the IQ loop. The repeater unit shall be capable of extending the operating 

distance of an IQ loop by as much as 1,000 feet (305 m) or more, depend-

ing upon IQ loop wire capacitance. The repeater unit shall suport both the 

original IQ and the newer IQ2  protocols.
The repeater unit shall provide one RJ-45 connector for input, and one 

RJ-45 connector for output. The repeater unit shall provide Power indica-

tors on the front and rear panels to indicate that the AC supply is connected 

and that power is applied. The repeater unit shall provide yellow Data Send 

and green Data Recieve indicators on the front and rear panels to indicate 

IQ loop data activity.
The repeater unit shall contain its own universal power supply for operation 

from 100VAC to 240VAC, and 47 Hz to 66 Hz. A standard IEC inlet shall be 

provided for AC line cord-set connection. 
The repeater unit shall meet or exceed the following general specifications: 

Power Consumption: 100VAC, 60 Hz: 3.70W, 50 Hz: 3.71W; 120VAC, 

60 Hz: 3.92W, 50 Hz: 3.92W; 220VAC, 60 Hz: 5.03W, 50 Hz: 5.03W;  

230VAC, 60 Hz: 5.23W, 50 Hz: 5.18W; 240VAC, 60 Hz: 5.59W, 50 Hz: 

5.41W.
The repeater unit shall meet or exceed the following IQ Bus data com-

munication specifications: Protection: The auto-reset feature is controlled 

by the microprocessor. Optically coupled 20-milliamp current loop receiv-

ers provide ground isolation. Data Rate: 38.4 K baud. Data Format: Asyn-

chronous binary serial data with 1 start bit, 1 stop bit, 8 data bits and 

no parity check. Interface Type: 20-milliamp current loop. Operation: Half 

duplex. Intelligence: 16-bit microprocessor. Transmission Distance: Vari-

able from 200 to 3,000 feet (61 to 914 meters) depending on wire capaci-

tance. 1,000 feet (305 meters) is typical with shielded 26 AWG twisted pair 

wire. More IQ repeaters or fiber optic transceivers can be used to cover 

greater distances.
The repeater unit shall meet or exceed the following mechanical specifica-

tions: Finish: Charcoal powder-coated steel chassis and front panel with 

Lexan

®

 front and rear overlays. Dimensions: 19-inch (48.3 cm) standard 

rack mount width (EIA RS-310-B), 1.75-inch (4.4 cm) height and 6.5-inch 

(16.5 cm) depth. Weight: 6 lbs., 4 oz (2.8 kg) net; 9 lbs., 5 oz (4.2 kg) 

shipping.
The repeater unit shall be designated the Crown IQ-RPT-3    .

Отзывы: