The power amplifi er shall be a solid-state two-channel model employing 
Class I (BCA

®

) output circuitry.

The amplifi er shall contain protection from shorted, open and mismatched 
loads, general overheating, DC, high-frequency overloads, under/over volt-
age, and internal faults.

If an amplifi er channel starts to overheat, the Thermal Level Control (TLC) 
circuit shall engage that channel’s input compressor in an amount propor-
tional to the amount of overheating, in order to generate less heat. If the 
channel becomes too hot for safe operation, the channel shall shut off, 
and the Thermal Indicator for that channel shall illuminate brightly to alert 
the user that a state of thermal stress or overload has caused the channel 
to shut down.

The front-panel controls shall be a power switch, Menu/Exit button, Previ-
ous button, Next button, Encoder 1 knob and Encoder 2 knob (Channel 
Level Controls).

Rear-mounted controls shall include a reset switch for the circuit breaker.

The recommended load impedance in Dual mode shall be 1/2/4/8/16 ohms. 
The load impedance in Bridge-Mono mode shall be 2/4/8 ohms. The ampli-
fi er shall be safe when driving any kind of load, including highly reactive 
ones.

The rear-mounted output connectors shall be two high-current, 50A Neutrik 
Speakon NL4MLP (mates with NL4FC or NL4)(one per channel), two pairs 
of high-current, 60A color-coded 5-way binding posts (for banana plugs, 
spade lugs or bare wire), two male XLR passive analog loop-through 
connectors, and one XLR active/re-clocked AES/EBU digital loop through 
connector.

The rear-mounted input connectors shall be a 3-pin female XLR analog 
input connector for each channel, and a 3-pin female XLR digital input 
connector that accepts a digital signal in the AES/EBU format.

The rear-mounted Ethernet connector accepts an RJ-45 connector for 
HiQnet™ or TCP/IQ™ networking and optional CobraNet™ transport from 
a standard network cable. Built into the connector shall be a yellow LINK 
ACTIVITY indicator that shows network activity, and a green 100Mb indica-
tor that shows a 100Mb network connection.

The rear-mounted Data indicator shall be a yellow LED that indicates 
HiQnet or IQ data activity. The rear-mounted Preset indicator shall be a 
yellow LED that fl ashes to signal the number of the current preset if active.

The I-T8000 shall be fully compatible with the HiQnet protocol and Harman 
Pro’s System Architect Software. The I-T8000CN shall be compatible with 
CobraNet networks.

Front panel indicators shall include an LCD Control Screen with white LED 
backlight to control the amplifi er’s setup and operation, a yellow Bridge-
Mode Indicator that illuminates when the amplifi er is set to Bridge-Mono 
mode, a green Ready Indicator (one per channel) that illuminates when the 
channel is initialized and ready to produce audio output and is off when 
the ampliifer is in standby mode via the software, a green Signal Indicator 
(one per channel) that illuminates to indicate the presence of input signals 
above –40 dBu, a red Clip Indicator that illuminates when the THD of the 
channel’s output signal reaches the onset of audible clipping (and illumi-
nates during Thermal Level Control (TLC) limiting, a red Thermal Indicator 
(one per channel) that illuminates when the channel has shut down due 
to thermal stress or overload, a red Fault Indicator (one per channel) that 

I-T8000

6/05                                                         137254-1E 

© 2005 Crown Audio

®

, Inc.

Specifi cations subject to change without prior notice. Latest 
information available at www.crownaudio.com. 
Crown, Crown Audio, BCA, and IQ System are registered trade-
marks of Crown International. HiQnet is a trademark of Harman 
International Industries, Inc. Printed in U.S.A.

Architectural & Engineering Specifi cations

I - T E C H   S E R I E S

fl ashes when the amplifi er output channel has stopped operating, a yellow 
Data Indicator that fl ashes during network data activity, a blue Power Indi-
cator that illuminates when the amplifi er has been turned on and AC power 
is available (and fl ashes when the AC line voltage is 15% above or below 
the nominal rated value), and a green AC Mains Present Indicator in the 
power switch that indicates AC power is present at the power cord.

The amplifi er shall include onboard DSP with 24-bit conversion and 32-bit 
fl oating-point processing, DSP presets in fi rmware and downloadable, load 
supervision, error reporting, and a global power supply with Power Factor 
Correction. 

The power amplifi er shall meet or exceed the following performance crite-
ria. Input sensitivity for rated output: adjustable in 0.1V steps from 1.4V to 
7.75V. Voltage gain: 39.3 dB to 24.5 dB. Rated output with both channels 
driven in Dual mode with 0.35% THD  (20 Hz to 20 kHz): 3500 watts per 
channel into 2 ohms, 4000 watts per channel into 4 ohms, and 2100 watts 
per channel into 8 ohms. Rated output in Bridge-Mono mode with both 
channels driven at 0.35% THD (20 Hz to 20 kHz): 7000 watts into 4 ohms 
and 8 000 watts into 8 ohms. Frequency Response at 1 watt, 20 Hz to 
20 kHz: ±0.25 dB. Signal to Noise Ratio below rated power, A-weighted: 
greater than 105 dB. Total Harmonic Distortion at full rated power: less 
than 0.35%. Intermodulation Distortion (60 Hz and 7 kHz at 4:1, from full 
rated output to –35 dB): less than 0.35%. Damping Factor (20 Hz to 100 
Hz): greater than 5000. Crosstalk (below rated power, 20 Hz to 1 kHz): 
greater than 80 dB.  Common Mode Rejection (20 Hz to 1 kHz): greater 
than 50 dB. DC Output Offset: less than ±3 mV. Input Impedance (nominal): 
20 kilohms balanced, 10 kilohms unbalanced. Maximum Input Level: +15 
dBu or +21 dBu, depending on input sensitivity. Latency (analog, digital 
inputs): 1.13 mS analog, 1.81 mS digital (96 kHz).

The amplifi er chassis shall be constructed of aluminum with a durable 
silver fi nish and shall be designed for dual-zone, microprocessor con-
trolled, continuously variable-speed forced-air ventilation from the front 
panel to the back panel. 

The dimensions of the amplifi er shall allow for 19 inch (48.3 cm) EIA 
standard (RS-310-B) rack mounting. The amplifi er shall be 3.5 inches 
(8.9 cm) tall, and 16.2 inches (41.1 cm) deep behind the rack-mounting 
surface.

The amplifi er shall weigh 28 pounds (10.5 kg).

The amplifi er shall be designated the Crown I-T8000.