background image

MANUAL

 

10

168

R

2

INSTALLATION & OPERATION 

MANUAL 

Self Generating Steam Full Jacket Kettles 

EL-20F, EL-30F, EL-40F, EL-60F

EP-20F, EP-30F, EP-40F, EP-60F

WARNING 

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read 

the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. 

IMPORTANT FOR FUTURE REFERENCE 

Please complete this information and retain this 

manual for the life of the equipment:

 

Model #:   ___________________________  
Serial #:   ___________________________  
Date Purchased:   ____________________  

CROWN FOOD SERVICE EQUIPMENT 

Middleby

 

Compan

y

 

70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9 

Telephone: 919-762-1000              www.crownsteamgroup.com 

Printed in Canada 

Содержание EL-20F

Страница 1: ...rating and maintenance instructions thoroughly before installing or servicing this equipment IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the...

Страница 2: ...injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death WARNING Improper installation operation adjustment alteration service or maintenance can cause proper...

Страница 3: ...O 10168R2 3 2013 07 17 TABLE OF CONTENTS DESCRIPTION PAGE 1 0 Service Connections 4 2 0 Installation 6 Introduction 8 3 0 Description 8 4 0 Capacities 8 5 0 Functioning Mode 9 6 0 Operation Instructio...

Страница 4: ...INSTALLATION AND OPERATION MANUAL SELF GENERATING STEAM FULL JACKETED KETTLES MODELS EL 20F TO EL 60F EP 20F TO EP 60F PART NO 10168R2 4 2013 07 17 1 0 SERVICE CONNECTIONS...

Страница 5: ...INSTALLATION AND OPERATION MANUAL SELF GENERATING STEAM FULL JACKETED KETTLES MODELS EL 20F TO EL 60F EP 20F TO EP 60F PART NO 10168R2 5 2013 07 17 1 0 SERVICE CONNECTIONS...

Страница 6: ...ed in accordance with 1 State and or local codes 2 In the USA the National Electrical code ANSI NFPA 70 latest edition In Canada the Canadian Electrical Code Part 1 CSA Standard C22 1 latest edition 2...

Страница 7: ...e provided Kettle must be grounded in accordance with requirements of the National Electrical Code or applicable local codes Ground kettle to terminal provided in control housing Once proper connectio...

Страница 8: ...d antifreeze sufficient not only to immerse and thereby protect replaceable electric heating elements but also provide the steam source during the steam generating process The heating elements are the...

Страница 9: ...ater the steam pressure attained in the jacket and consequently the quicker the cooking process For example steam pressurized at 30 p s i attains a temperature of 274 Fahrenheit Since air is an unsuit...

Страница 10: ...be in the green area of the gauge indicating 25 30 In Hg 630 730 mm Hg of vacuum If reading is not low enough follow VENTING procedure in Troubleshooting section prior to using kettle Place power swit...

Страница 11: ...NO 10168R2 11 2013 07 17 6 0 OPERATION INSTRUCTIONS Continued When cooking is finished set thermostat knob and power switch to OFF position Pour finished product from kettle using tilt handle Be care...

Страница 12: ...ifferent product Before cleaning check that the kettle has cooled enough to touch it 1 Rinse the inside of the kettle thoroughly and drain to remove any food particles 2 Using a nylon brush clean the...

Страница 13: ...aw off valve open when the kettle is not in use DAIRY DRAW OFF VALVE CLEANING 1 Remove the plug by first removing the handle then turn the plug to line up with the pin and pull with both hands It is i...

Страница 14: ...itions salt air may require more thorough and frequent cleaning or the life of the equipment could be adversely affected STAINLESS STEEL To remove normal dirt grease or product residue from stainless...

Страница 15: ...ul Heat tint can normally be removed by the foregoing but tint which does not respond to this procedure calls for a vigorous scouring in the direction of the polish lines using SCOTCH BRITE scouring p...

Страница 16: ...are noticed within the valve body testing must be performed more often A try lever test should also be performed at the end of any non service period CAUTION Hot high pressure fluid may be discharged...

Страница 17: ...for the kettle to operate the following procedure must be followed The kettle must be cool before proceeding with the following steps 1 Trip the safety relief valve lever to relieve all pressure from...

Страница 18: ...water level is inadequate in jacket Follow LOW WATER LEVEL instructions 3 If water level is sufficient and kettle refuses to operate then check that Tilt Interlock Switch in Console is fully engaged...

Страница 19: ...vented removed for proper heating Use the following procedures to vent air 1 Place power switch ON with kettle empty 2 Set temperature control thermostat to 10 Heat kettle until indicator light goes o...

Страница 20: ...N IN CASE OF EMERGENCY Fort Saskatchewan Alberta 780 998 8282 Sarnia Ontario 519 339 3711 Varennes Quebec 450 652 1000 Product DOWFROST HD HEAT TRANSFER FLUID DYED Product Code 04632 Effective Date 2...

Страница 21: ...peated exposures may cause flaking and softening of skin INGESTION Single dose oral toxicity is considered to be extremely low No hazards anticipated from swallowing small amounts incidental to normal...

Страница 22: ...r INGESTION No adverse effects anticipated by this route of exposure incidental to proper industrial handling INHALATION Remove to fresh air if effects occur Consult a physician NOTE TO PHYSICIAN No s...

Страница 23: ...pe are preferred if available General purpose synthetic foams including AFFF or protein foams may function but much less effectively Do not use direct water stream May spread fire MEDIA TO BE AVOIDED...

Страница 24: ...NG AND STORAGE No special handling requirements data available HANDLING See Section 8 Exposure Controls Personal Protection STORAGE See Section 10 Stability and Reactivity 8 EXPOSURE CONTROLS PERSONAL...

Страница 25: ...ABILITY AND REACTIVITY CHEMICAL STABILITY Thermally stable at typical use temperatures CONDITIONS TO AVOID Avoid use temperatures above 450 F 232 C Product can degrade at elevated temperatures Generat...

Страница 26: ...for major component s Material is readily biodegradable Passes OECD test s for ready biodegradability Degradation is expected in the atmospheric environment within minutes to hours ECOTOXICITY Based...

Страница 27: ...PORTATION D O T For D O T regulatory information if required consult transportation regulations product shipping papers or contact your Dow representative CANADIAN TDG INFORMATION For TDG regulatory i...

Страница 28: ...Amendment and Reauthorization Act of 1986 SARA Title III and is considered under applicable definitions to meet the following categories Not to have met any hazard category TOXIC SUBSTANCES CONTROL AC...

Страница 29: ...formation System WHMIS Classification for this product is This product is not a Controlled Product under WHMIS CANADIAN ENVIRONMENTAL PROTECTION ACT CEPA This product contains one or more substances w...

Отзывы: