background image

MANUAL

 

10

060

R1

INSTALLATION & OPERATION 

MANUAL 

 

'LUHFW6WHDP&DELQHW%DVH&RQYHFWLRQ6WHDPHU

'&;

WARNING 

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read 

the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. 

IMPORTANT FOR FUTURE REFERENCE 

Please complete this information and retain this 

manual for the life of the equipment:

 

Model #:   ___________________________  
Serial #:   ___________________________  
Date Purchased:   ____________________  

CROWN FOOD SERVICE EQUIPMENT 

Division of Middleby Canada Company Inc

70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9 

Telephone: 919-762-1000              www.crownsteamgroup.com 

Printed in Canada 

Содержание DCX-16

Страница 1: ...roughly before installing or servicing this equipment IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model _______________________...

Страница 2: ...lation operation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing operat...

Страница 3: ...SE CONVECTION STEAMER MODEL DCX 16 PART NUMBER 10060R1 3 2007 02 16 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes 2 1 0 Service Connections 4 2 0 Installation Instructions 5 3 0 Operating Instruc...

Страница 4: ...INSTALLATION AND OPERATION MANUAL DIRECT STEAM CABINET BASE CONVECTION STEAMER MODEL DCX 16 PART NUMBER 10060R1 4 2007 02 16 1 0 SERVICE CONNECTIONS...

Страница 5: ...ocations marked on floor and insert proper anchoring devices 5 Set unit back in position and re level left to right and front to back 6 Bolt and anchor appliance securely to the floor 7 Seal bolts and...

Страница 6: ...lbs of steam per hour to the appliance From the foregoing to use pipe line would most likely prove inadequate An extremely important consideration is the pressure drop that will occur through the ste...

Страница 7: ...approximately 32 psi from an original boiler supply of 40 psi It is suggested that wherever possible the steam supply line to the appliance be a separate line from the steam source If the appliance m...

Страница 8: ...be cooked into compartment and shut door 2 Set timer to cooking time desired Cooking cycle may be interrupted at any time by opening door and resumed again by closing door 3 When buzzer sounds it ind...

Страница 9: ...ch day or as required with a mild detergent and water to prevent bacterial growth and odours 3 Remove drain screens from inside compartment drains Using a plastic bottle brush and mild detergent clean...

Отзывы: