Crow TALON SERIES Скачать руководство пользователя страница 2

 

13

 

 

14

 

 

15

 

LED ENABLE/DISABLE SETTING -  

JUMPER “JP3” (FIG.4)

 

Position Right “On” - LED ENABLE 

The RED LED will activate when the SR-X 

 Is in alarm condition. 

Position Left “Off” - LED DISABLE 

The LEDS are disabled. 

Note: the state of the Jumper “JP3” does not 

affect the operation of the relay. 

When an intrusion is detected, the LED will 

activate and the alarm relay will switch into alarm 

condition for 1.6 sec. 

 
LED

 

INDICATORS (Fig.4) 

YELLOW  LED - MW detection’s 

GREEN    LED - PIR detection’s 

RED         LED - Alarm 

 

 

 

TEST PROCEDURES

Wait one-minute warm-up

 

time after applying  

12 Vdc power. Conduct testing with the protected 

area cleared of all people. 

 Walk test 

1.  Remove front cover.                                             

Set LED to ON position. 

2.  Reassemble the front cover. 

3.  Start walking slowly across the detection zone. 

4.  Observe that the red LED lights whenever 

motion is detected. 

5.  Allow 5 sec. between each test for the detector 

to stabilize. 

6.  After the walk test is completed, you can set the 

LED to OFF position. 

NOTE:

  

Walk tests should be conducted, at least once a 

year, to confirm proper operation and coverage of 

the detector. 

 

 

FIG. 5 - WA PIR + MW DETECTION 

PATTERN 

 

16

 

 

17

 

 

18

 

FIG. 6 - LONG RANGE CURTAIN LENS 

 

 

 

PATTERN SCALE CALIBRATION 

To calibrate the MW pattern scale, You need the 

size of the room (length and detection angle). 
For Doppler pattern see fig.7 and table1 on  

Page 18, where H – Doppler pattern max; 

                         ## - zone number;   

                          a – angle;  

                          X,Y – appropriate coordinates of    

Doppler pattern. 

The potentiometer RV1(Fig. 4) adjusts according 

to protected area range. 

The potentiometer at mid-scale is equivalent to a 

distance of 15m, at min-scale – 7m and         

max-scale - is used with LR lens only. 

 

 

 

 

FIG. 7 - MW PATTERN 

 

 

 

 

 

 

 

Table 1: 

##

0

1

2

3

4

5

6

7

8

9

10

a

180° 130° 100°

84°

75°

70°

60°

52°

40°

30°

20°

X

0

3

6

9

12

15

18

21

24

27

28,5

Y

10,5

6,09

7,15

6,98

8,01

10,5

10,39 10,24 8,73

7,23

5,03

X,Y are corresponds (m) of pattern points 

when H=30m 

19

 

 

20

 

 

21

 

 

LENSES-INTERCHANGEABLE HARD 

TYPE LENSES PATTERNS

 

                 Standard               Options 

COVERAGE       WIDE                       LONG RANGE    

                          ANGLE                        CURTAIN  
                           90.5                                   9  

                      15m x 21m                        21m x 3.5m        

                      (50ft x 70ft)                       (70ft x 11ft)    
TOTAL 

ZONES                  18 (36)*                             5(10)

                      

*7 (14) long range, 5 (10) intermediate,  

6 (12) short range.

  

REPLACING THE LENS 

1.  Remove the front cover by inserting a flat 

screwdriver in the appropriate slot (fig.1). 

2.  Using a small flat screwdriver, press on left, 

right and middle snaps of the lens and pull the 

lens out from its place (front cover side) (fig.8). 

3.  Replace a new WA or LR lens. 

4.  Push the lens to its place by pressing again 

from outside of the front cover until a click is 

heard (fig.8). 

5.  Replace front cover. 

 

 

FIG. 8 - REPLACING THE LENS  

 

 

TECHNICAL SPECIFICATIONS 

Detection Method 

Dual element PIR & microwave pulse 

 

Doppler 

Maximum ripple 

2.4Vdc peak to peak at 12Vdc 

Power Input 

8.2  to 16 Vdc 

Current Draw 

Active :    25.5 mA 

 

Standby:  16.5 mA 

Temperature 

 

Compensation 

YES 

Alarm Period 

2 +/- 1  sec 

Alarm Output 

N.C 28Vdc 0.1 A with 10 Ohm series        

 

protection resistors 

Tamper Switch 

N.C 28Vdc 0.1A with 10 Ohm series 

 

protection resistor - open when cover 

 

is removed 

Warm Up Period  

1 min 

LED Indicator 

Yellow LED is blinking during warm up 

 

period and self testing,  

  

Red LED is ON during alarm 

   

Red LED: UNIT ALARM 

    

Green LED: PIR CHANNEL 

   

 

Yellow LED: MW CHANNEL 

 

22

 

 

23

 

 

24

 

TECHNICAL SPECIFICATIONS (CONT.) 

Operating Temperature 

-20 C to +50 C(-4 F to +122 F) 

RFI Protection 30V/m  10  - 1000MHz 
EMI Protection  

50,000V   of electrical 

interference    

from lightning or power through 

Visible Light Protection 

stable against halogen light 2.4 m  

 

 

(8ft) or reflected light 

MW output power 

min + 5 dBm IERP 

Microwave frequency 

     2.45 GHz       

MW harmonic emission 

-20dBm 

Dimensions 

137mm x 65mm x 49mm 

  

(5.3” x 2.6” x 1.9”) 

Weight    

 

130 gr. (4.,6  oz) 

               

CROW

 reserves the rights to change 

specifications without prior notice 

 

(

& % & ) ( *

& * + * & &

* + % ) , -

. - /

* ) 0

( %

0

& ) 1

) &

2

  !

!

 

"

#

$

%

$

$

#

&

$

$

$

'

$

(

%

)

*

$

$

%

&

+

,

$

$

$

,

,

,

-

$ .

$

$

.

%

&

.

&

.

%

$

*

$

$

$

*

$

$

/

0

$

$ .

$

,

#

$

$

,

0

%

$

$

$

#

0

$

#

,

 

CROW ELECTRONIC ENGINEERING LTD. 

ISRAEL:        

57 Hamelacha St., Holon 58855 

                      

Tel:  972-3-5569937 /8 /9 

                      

Fax: 972-3-5592981 

                     

E-mail: 

[email protected]

 

USA:                 

2160 North Central Road, 

                     

Fort Lee, N.J. 07024 

                     

Tel: 1-800-GET CROW  

                     

or     (201) 944 0005 

                     

Fax: (201) 944 1199 

                     

E-mail: 

[email protected]

 

AUSTRALIA:    

429 Nepean HWY Brighton East Vic 3187 

                      

Tel:  61-3-9596 7222 

                     

Fax: 61-3-9596 0888 

                     

E-mail: 

[email protected]

    

POLAND:     

VIDICON SP. ZO. O. 

                     

15 Povazkowska St. 

 

01 – 797 Warsaw  Poland 

                      

Tel:   48 22 562 3000 

                      

Fax:  48 22 562 3030 

                      

E-mail: 

[email protected]

 

LATIN AMERICA: 

CROW LATIN AMERICA  

 

5753 NW 151

ST

.Street 

 

MIAMI LAKES, 

 

FL 33014 – USA 

 

Tel:  +1-305-823-8700 

 

Fax: +1-305-823-8711 

 

E-mail: 

[email protected]

 

ITALY:        

     DEATRONIC 

 

  VIA Giulianello 4/14  

 

  00178 ROMA, ITALY 

          

Tel:  +39-0676-12912 

          

Fax: +39-0676-12601 

          

E-mail: 

[email protected]

 

            7151288_B

 

90.5 °

 

30m

 

0m

 

5m

 

10m

 

15m

 

WA lens pattern 90.5 ° (PIR)

 

MW  pattern 

5m

 

10m

 

15m

 

30m

 

18m

 

10m

 

5m

 

         

SIDE VIEW

 

TOP VIEW

 

H

0

2

1

3

4

5

6

7

8

9

10

70’

21m

45’

13.6

12’

3.6

6’

2.4

8’

2.4

1.5’

0.4

0’

0

9º °

0’

0

SIDE VIEW

TOP VIEW

2

.

4m

 