thecrowgroup.com
Page | 33
Radio Zones
Parameter
Description
Default Configuration
Name
Enter name to identify the Zone
Zone #
Add Zone (Learn Radio
zone)
Radio detector must be enrolled into the panel before it can
be used.
Select zone # , Add Zone -> Link Type :ISM or DECT , Device’s
ID, Device type
Note
:
The pairing of DECT ULE device must be preliminarily
performed from "Communication"
→
"DECT"
→
"Learn DECT
Device".
When the DECT device pairing is done, then you can go to
"Radio Zones" and assign the DECT device ID to a zone.
Delete radio zone
Removing radio zone from the system.
-
Zone Config
This function set remotely the radio zone parameters such as
led on/off, pulse detection, Pet immunity, Gain level, etc.
Dedicated menu
according to detector
type enrolled
Radio Zone Module
Select device type “ ISM “ for RF devices or “DECT” for DECT
devices.
Zone Configuration –features & options examples:
Detector
PIR
Wireless
Available Options
LED(s) state
: Activation or not of the LED indicators
Supervision
: Time period between each supervision in minute (from 1 to 30)
Pet Immunity
: Activation of up to 25Kg Pet immunity
Number of Pulses
: Pulse count for each motion detection
Sensitivity
: PIR Sensitivity
2
MAG
-
SH
Wireless Door / Window Magnet
Available Options
LED Enable
: Activation or not of the LED indicators