thecrowgroup.com
Page | 26
Time Zone Assignment
Parameter
Description
Default Configuration
Time Zones
If area assigned to time-zone it will automatically armed
when time-zone starts and disarmed when finished. You
can assign more than one time-zone to each area. If
assigning multiple time-zones you should insure that they
do not overlap as this could cause confusion
Signals to Output
Parameter
Description
Default Configuration
Arm Area Indication
to Outputs
For monitoring purposes, an Arm indication can be assigned to
an Output.
It could be used to start a video recorder or similar device.
Each Area can have a separate arm indication assigned to a
different output if required
No Outputs selected
Stay Arm Area Indication
to Outputs
For monitoring purposes, a Stay Arm indication can be
assigned to an Output. Each Area can have a separate
indication assigned to a different output if required
No Outputs selected
Disarm Area Indication
to Outputs
For monitoring purposes, a Disarm indication can be assigned
to an Output. Each Area can have a separate disarm indication
assigned to a different output if required
No Outputs selected
Area account numbers
Parameter
Description
Default Configuration
Area Account numbers
When system sends a report to a monitoring station there
must be a unique account number programmed in report
channels from 1-7 to identify the panel. There is an account
code for each area.
The account code is 4 digits. Each digit can be a number from
0-9 as well as the special characters B, C, D, E & F. For SMS
report channels no need to define the account number.
All account in report
channels from 1-7 are
set "0" except the
channel #8 with account
"8000" for CrowCloud™
connection
Beeps to Keypads
Parameter
Description
Default Configuration
Area Armed Exit Delay Beeps
to Keypad
This option is using for monitoring purposes of exit delay at
arming by keypad beeping. If the option marked for specified
area corresponded keypad will start beeps during time of arm
exit delay, but no longer than given by buzzer reset time.
Enable for all keypads
Area Stay Armed Exit Delay
Beeps to Keypad
This option is using for monitoring purposes of exit delay at
stay arming by keypad beeping. If the option marked for
specified area corresponded keypad will start beeps during
time of stay arm exit delay, but no longer than given by buzzer
reset time.
Disable