CROW ELECTRONIC ENGINEERING LTD. FW NEO 9F Скачать руководство пользователя страница 1

INSTALLATION INSTRUCTIONS 

F W   N E O   9 F  

 

WIRELESS PIR WITH PET IMMUNITY UP TO 20 Kg 

PRODUCT FEATURES 

 
The

 

FW NEO 9F is an advanced, fully supervised low-

current wireless PIR that includes a FreeWave 
transmitter. Both transmitter and detector circuits are 
powered by long life Lithium battery. 
Each FW NEO 9F has a unique ID code (This code is 
impossible to reproduce). Compatible FreeWave 
receivers are designed to “learn” specific IDs and 
respond only to them. 
Following detection, FW NEO 9F triggers the on-board 
transmitter that transmits its specific FreeWave ID 
followed by an alarm signal and status designators for 
battery condition. If detector cover is removed Tamper 
Event triggers the on-board transmitter. 
 Alarm and other data are forwarded to the alarm 
control panel. A periodic test transmission for 
supervision purpose takes place automatically once in 
7 min. The receiver is informed that the particular 
detector is taking an active part in the wireless security 
system. 
The FW NEO 9F has unique Alarm Power Saver (APS) 
mechanism that enables transmitter activation only 2 
min after the last movement has been detected. 

 State-of-the-art wireless security system 

 Low current

 

ASIC PIR Technology

 

  Powered by a 3Volt Lithium battery 

  Battery life : up to 4  years 

  Built in Automatic Power Saver (APS) 

  Frequency Band: 916.5MHz 

 

 Low Battery

 

condition signal transmission

 

 Test

 

mode for PIR coverage and

 

RF signal. 

  Range up to 300 m at free space. 

  Height installation calibration free (1.5m - 3.6m).  

  Unique ID number 

The FW NEO 9F provides 

pet immunity

 up to 20Kg. Pet 

active bellow 1m. 
The Wireless PIR transmits the following events data: 

SUPERVISION

 - a periodical transmission.

 

Every 7 min indicates detector’s presence. 

ALARM

 – alarm transmission triggered by PIR 

intrusion detection.  

LOW BAT

 – Whenever the battery reaches a pre-set 

low level (2.4V) Battery Low signal will be sent with the 
next message (Supervision, Alarm, etc.) 

TAMPER

 – Whenever the FW NEO 9F cover is 

removed or the unit teals from the wall, a message 
"Tamper" will be transmitted. 

APS  

The unique APS (Automatic Power Saver) function built 
in the detector enables a battery life span up to four 
years. The detector will transmit only when the last event
has occurred more than 2 minutes prior to the current 
one.

  

 

 

 

SELECT MOUNTING LOCATION 

Choose a location most likely to intercept an intruder. 
(Our recommendation is a corner installation). See 
detection pattern – fig.2. The quad-element high 
quality sensor detects motion crossing the beam; it is 
slightly less sensitive detecting motion toward the 
detector. 
Recommended mounting height – 1.8m-2.4m. 
AVOID THE FOLLOWING LOCATIONS 

  Facing direct sunlight. 

  Facing areas that may change temperature 

rapidly. 

  Areas where there are air ducts or 

substantial airflows. 

The FW NEO 9F performs better when provided with a 
constant and stable environment.  

DETECTOR INSTALLATION

 

The detector can either be wall or corner mounted.   
If ceiling or special wall mounting is required, use the 
optional bracket base. Refer to bracket description.   
(See fig. 4). 

1. To remove the front cover, unscrew the holding screw 

and gently raise the front cover. 

2. To remove the PC board, carefully unscrew the 

holding screw located on the PC board. 

3.  Break out the desired holes for proper installation.  

 

Fig. 1

 

4. Mount the detector base to the wall, corner or ceiling. 

(For option with bracket see fig.4). 

5. Reinstall the PC board by fully tightening the holding 

screw.  

6. Install battery in the battery holder according polarity.

7. Replace the cover by inserting it back in the 

appropriate closing pins and screw in the holding 
screw. 

 

RSSI-RF SIGNAL INDICATION 

The control panel has “RF Signal quality Indication” 
for each transmitter in order to help the installer to 
define best location for the detector from RF point 
of view. 

 

The indication value is between 1 and 100, where 
100 is the best RF received signal. If the RSSI 
indication is less then 30, it is a sign for weak RF 
link, try to find a better installation for the PIR.  
NOTE:  See control panel installation instruction. 
 

ID REGISTRATION

 

Refer to the system receiver’s installation instructions 
and follow the procedure given there for “learning” 
detector IDs.  
Perform transmission by pressing and releasing 
tamper switch for learning it by the control panel 
receiver.  
Make sure that the receiver is at learning mode - 
according to control panel installation instruction. 
NOTE: It is recommended to power up the detector and 
let the system receiver “learn” the detector’s ID before 
actual installation. 
 

TESTING THE DETECTOR 

TEST PUSH BUTTON   

Push Button is located at the lower left side of the 
detector. This button (switch) is used to activate the 
walk and RF transmission test of the detector. 

WALK TEST 

Push the Test button for 1 sec and release, the LED 
will blink 3 times, the LED and a Transmission will 
activate on the every detection. 
The test mode period is 2 min; at the end of the test 
mode the LED will blink fast 4 times to indicate the end 
of the Test.

 

ALARM TRANSMISSION TEST 

Pressing Push Button for at least 3.0 sec enables the 
alarm transmission test feature, which activates 11 
transmission signals at 6 sec intervals (total test time 
about 1 min).  
Please check, that the receiver unit indicates 11 
events.  
This test enables to activate the alarm transmission 
immediately, and bypass the APS 2 minutes limitation.  
To check this function it is necessary to verify that the 
control panel display shows 
  
 
 
X- zone number from which the massage received.  

Tamper transmission test. 

Change of the tamper switch state will cause tamper 
transmissions. Verify on the control panel that display 
shows  

 

 

 
Transmission range test. 

By Alarm transmission test (Pressing Push Button for 
more then 3.0 sec) it’s enable to check the RF 
transmission quality (RSSI). Special indication at the 
control panel displays continuously the received RF 
signal quality.  

 

 

 
 

 

 

 

Fig.2 

 
 

 

 

Fig.3 

       7101799_A 

 

  

 

 

                          - 1 - 

 

 

 

 

 

    

B.  Use for flat wall 

mounting 

C. Corner 

mounting - use 
all 4 holes. 
Sharp left or 
right angle 
mounting - use 
2 holes (top 
and bottom) 

D. For bracket 

mounting 

E. For back 

tamper 

Zone # X Open

Trouble Zone # X  

C E 

ANTENNA

 

BATTERY

 

2/3AA 3V

 

LED

 

TEST 

PUSH

 

BUTTON

PYROSENSOR

 

PET

 

IMMUNITY

 

ADJUSTMENT

 

JUMPER

 

TAMPER

BACK

 

TAMPER

 

(PS)

 

SENSITIVITY

 

ADJUSTMENT

 

JUMPER

 

Отзывы: