ULTRAVIOLET WATER PURIFICATION SYSTEMS
INSTRUCTION MANUAL
MODEL:
______________________
VOLTAGE:
____________________
SERIAL #: _____________________
NSF/ANSI 55 CLASS A CERTIFIED
Страница 1: ...ULTRAVIOLET WATER PURIFICATION SYSTEMS INSTRUCTION MANUAL MODEL ______________________ VOLTAGE ____________________ SERIAL _____________________ NSF ANSI 55 CLASS A CERTIFIED...
Страница 2: ...all 1 888 407 9997 or email info uvpure com or visit www uvpure com INSTRUCTION MANUAL Copyright UV Pure Technologies Inc 2005 All rights reserved No part of this document may be photocopied reproduce...
Страница 3: ...s two proprietary high output UV lamps with elliptical reflectors that target pathogens with radiation from 360 to deactivate pathogens and provide microbiologically safe drinking water Crossfire Tech...
Страница 4: ...now be 100 certain that when you turn on the tap every drop is microbiologically safe to drink The Hallett outperforms conventional systems by delivering highly effective UV dosage rates for the inac...
Страница 5: ...ls Needed 8 Location on a wall 9 Time Required 9 Assembling the Unit 11 Connecting the Pipes 12 Parallel Installation 14 Plugging in the Hallett 15 Flushing Instructions 16 External Alarm Contacts 16...
Страница 6: ...nce more than 75 percent transmission of ultraviolet light if there is color in the water the UV transmittance may fall below 75 and the system will not provide the necessary UV dose for safe drinking...
Страница 7: ...r cord entry of the unit See Figure 1B For convenience the front cover of the manual should also contain model number and operating voltage 120Vac Models 220 240Vac Model Hallett 13 104W 1 5A max 50 6...
Страница 8: ...s Other Materials Needed The Hallett requires male NPT fittings for the hose connections and also the solenoid valve make a note of the size 1 These fittings and any piping compatible with the plumbin...
Страница 9: ...llowing clearances Hallett 13 See Figure 1A and 1D 14 36 cm above the unit for lamp replacement 12 30 cm minimum below the unit for service access 7 18 cm on each side of the unit for service access H...
Страница 10: ...CEMENT RECOMMENDED CLEARANCE FRONT VIEW TOP VIEW FLEXIBLE TUBING FLEXIBLE TUBING 131 2 34 3cm 71 2 19 1cm LEAVE THIS AREA CLEAR OF PIPES FOR LAMP REPLACEMENT 7 17 8cm MIN 7 17 8cm MIN WALL 81 2 21 6cm...
Страница 11: ...UAL FORCE OPEN PLUG FOR VALVE DO NOT CONNECT ANY OTHER DEVICE IN THIS RECEPTACLE FLOW PIPE INSULATION MUST BE INSTALLED SECURE CABLE TO WALL POWER CORD ENTRY LOCATION OF FUSE FLOW TYPICAL INSTALLATION...
Страница 12: ...holes in the upper brackets Then install the bottom two fasteners Do not install the unit horizontally Leave clearance over the unit for lamp removal Connecting the Pipes We recommend that a qualifie...
Страница 13: ...tening a metal fitting into the valve will cause it to crack Do not over tighten Keep the coil of the valve pointing upward to prevent water from dripping on it Water will not flow backwards through t...
Страница 14: ...the inside of the unit to get wet Before opening the water supply double check all connections and cover the top of the unit with a rag or some plastic to prevent water entry Close any faucets you op...
Страница 15: ...VALVE ESSENTIAL CHECK VALVE ESSENTIAL TYPICAL INSTALLATION OF PARALLEL UNITS Figure 1E Plugging in the Hallett Step 1 Ensure that the covers on the unit have been installed and the unit is securely f...
Страница 16: ...structions Flushing the system is required after installation or after any disassembly and cleaning Flushing may also be required to remove colored water from the unit Most filters if installed also r...
Страница 17: ...This is accomplished by removing the screw that secures the top cover Remove the top cover Gently remove the front cover and hold it a couple of inches off from the body of the unit You must disconnec...
Страница 18: ...ions cannot be avoided the Cold Air Kit should be installed The kit consists of two cover plates and two lamp insulators The cover plates are to be placed on the top aluminum plate to cover the convec...
Страница 19: ...ND GLASS LAMP WATER NOT CLEAN HOURGLASS RESET BUTTON RESET LAMP TIMER Figure 2 There are three indicating lights and a pushbutton on the front panel See Figure 2 At the top beside the FAUCET AND GLASS...
Страница 20: ...to beep and the solenoid valve remains closed The green light illuminates when the UV lamps have reached full power and there are no system faults New lamps may take from a few moments to several hour...
Страница 21: ...does not work with sediments or heavy biofilm and encrustations which must be removed mechanically The accepted practice for sanitizing the household or facility plumbing involves adding 50 ppm chlori...
Страница 22: ...ault does occur the solenoid valve will close preventing water from flowing The green light will go out one of the red lights will illuminate and the alarm will beep The fault must be corrected to ret...
Страница 23: ...insulation to prevent condensation runoff Dry up all remaining water and inspect lamps for water spots and clean if necessary see section on Replacing and Cleaning UV Lamps Inspect reflectors for wate...
Страница 24: ...conds after replacing the lamps The unit will now disinfect normally again Push the Reset button to silence the alarm Continue to run the lamps for up to several hours If the situation is not remedied...
Страница 25: ...ly again and the solenoid valve will open Water Quality red light on and one beep heard every 5 seconds The ultraviolet light from the lamps cannot penetrate the water if the water is colored from tan...
Страница 26: ...er shutting down the system for seasonal use will extend lamp life Your unit has an internal timer to keep track of the lifetime of the lamps It will issue a warning when the end of their lifetime app...
Страница 27: ...uous use and can burn your skin if touched Allow lamps to cool for five minutes before removing them Step 2 Remove the top cover by removing the screw Step 3 Slowly lift the old lamps out of the unit...
Страница 28: ...w moments to several hours to reach full power Continue to run the unit until the lamps reach full power The solenoid valve will remain closed until the lamps have reached full power Draining the Unit...
Страница 29: ...the unsatisfactory conditions Follow the steps below to inspect the quartz and disassemble the unit for quartz cleaning Caution Always unplug the unit before performing any maintenance Never operate...
Страница 30: ...ck and easy procedure that works well in most cases Step 1 Fill a bucket or container with water before shutting off the water supply since you will need the water later to clean the quartz sleeve 3 A...
Страница 31: ...o uvpure com or visit www uvpure com 31 clean water If fouling remains repeat procedure Step 9 Once the unit is clean reassemble the unit including the motor and top hose connection Step 10 Slowly ope...
Страница 32: ...111 1 BTM END CAP ASSY MOTOR END 6 350005 2 QUARTZ O RING SEAL 7 350009 1 WIPER O RING SEAL 8 E300108 1 WASHER TEFLON 5 8 ID X 1 OD 9 350007 1 U CUP SEAL FOR WIPER 10 E300142 1 BEARING BASE WIPER SHAF...
Страница 33: ...FIP FLEXIBLE HOSE WIPER SHAFT ASSY BEARING O RING SEAL BEARING BASE WIPER SHAFT U CUP SEAL FOR WIPER 4 2 1 1 1 1 BRACKET TOP PLAIN END WIPER O RING SEAL QUARTZ O RING SEAL BTM END CAP ASSY MOTOR END B...
Страница 34: ...ss Step 6 Remove the top end cap 2 by lifting it straight up Step 7 Disconnect the wiper motor 17 from the bottom bracket 4 by undoing the three nuts See Figure 4C Pull off the motor plate and foam pa...
Страница 35: ...artz is still not clean it requires replacement This is done by removing the bottom quartz seal assembly Step 5 Remove the bottom Bracket 4 by undoing the four fasteners in an alternating pattern top...
Страница 36: ...his will help center both parts Figure 4D Step 3 Replace the top bracket 1 over the top end cap 2 The collar of the end cap will fit snugly in the hole in the bracket and align itself Tighten the fast...
Страница 37: ...r email info uvpure com or visit www uvpure com 37 Caution Do not operate the unit if there are any leaks at the piping connections or within the unit Step 7 Reinstall the right hand cover panel Ensur...
Страница 38: ...r Array E100043 Quartz Sleeve Kit E300173 Contains one E300117 two O ring seals 350005 Quartz O ring seal 350005 Reflector Assembly E300125 Seal washer pair flexible hose E500019 Contains two E300135...
Страница 39: ...ns one E100034 Seal Kit C500008 Contains 350007 2 x 350014 350009 E300108 2 x C300017 650066 650099 Replacement parts and Service are available from your dealer or UV Pure Technologies Inc 60 Venture...
Страница 40: ...itted or translated to another language without the prior written consent of UV Pure Technologies Inc For additional info call 1 888 407 9997 or email info uvpure com or visit www uvpure com 5 SERVICE...
Страница 41: ...chaser and to the original installation location Date of purchase can be verified by the purchase receipt or filled out warranty card that has been registered with UV Pure The warranty for any compone...
Страница 42: ...lth standards This system is not intended to convert wastewater or raw sewage to drinking water The system is intended to be installed on visually clear water NSF ANSI 55 defines wastewater to include...