Original User manual
7
7
6
5. Putting into operation
Take the CPG 6000 DEV out of the packaging and set it down at the intended assembly site. The machine must
be horizontal. Remove dirt and dust so that the air cooling of the generator cannot draw in any foreign objects.
The generator is equipped with a low-oil safety feature. This convenient technology automatically stops the en-
gine when the engine oil falls below the required minimum level. Because the generator is delivered without oper-
ating materials, it is essential that it is filled with engine oil before first use. The engine can be started only when a
sufficient quantity of the oil has been filled. When filling with the operating materials, observe all of the relevant in-
structions and specifications cited in these operating instructions.
5.1.
Tests before start-up
Check the battery connection
Before start-up, the “- terminal” of the battery must be connected. Otherwise, it is not possible to operate the gen-
erator. The “+ terminal” is already connected and insulated using a terminal cover.
Note:
When connecting the terminals, first connect the “+ terminal” and then the “- terminal”.
When disconnecting the terminals, first disconnect the “- terminal” and then the “+ terminal”.
Check the engine oil level
Note:
Always switch the engine off before checking the engine oil level.
Use a suitable 4-stroke oil for diesel engines. The use of SAE 10W-30 is recommended for general use in differ-
ent temperature ranges. The other viscosities stated in the table can be used if the average temperature in the
area of application lies in the stated range.
1. Open the engine cover to check the engine oil. (Fig. 1 no. 5)
2. Then open the oil filler screw (fig. 6) and fill engine oil. Fill the oil up to the top mark of the dipstick.
Check the oil level
1. Remove the oil filler screw and clean the dipstick using a clean cloth.
2. Insert the dipstick back into the oil filler port without turning it. If the
oil level is below the bottom end of the dipstick (min.) add engine oil
to it.
3. Add engine oil until the oil reaches the top mark (max.) of the dip-
stick.
4. Insert the dipstick correctly and screw it on again.
Oil fill capacity: approx. 1.65 l
Check the fuel level
1. Check the fuel gauge (fig. 7 no. 16) and fill the fuel tank if the fuel level is
too low.
2. Use Diesel only Petrol or E10 can damage the generator considerably.
3. Remove the tank cap (fig. 7 no. 2)
4. Fill with fuel to a maximum level of the bottom of the filter insert (fig. 8, no.
17).
5. Close the tank cap.
5