background image

Instruction Manual

                       

Model 2097-07  

Amplifier  

April 2010   Rev B   

CROSS TECHNOLOGIES, 
INC

AGC

MGC

DC

MGC

GND AGC

2097 AMPLIFIER

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment. Printed in USA.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB:  www.crosstechnologies.com 

E-MAIL:  [email protected]

Содержание 2097-07

Страница 1: ...ated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be sure to include the equipment mode...

Страница 2: ...od of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire...

Страница 3: ...0 to 100 MHz IN ATT ATT AGC CONTROL 200 MHz IF LP 2097 07 IF AMPLIFIER BLOCK DIAGRAM Input Characteristics Impedance RL 50 10 dB Frequency 50 to 100 MHz Input Level Range 0 to 80 dBm Input 1dB 5 dBm O...

Страница 4: ...tors Figure 2 2 shows front panel controls and indicators 2 3 Input Output Signals Figure 2 3 shows the input and output signals to the 2097 DS2 DC Power LED Light green when DC Power is present R40 M...

Страница 5: ...70 MHz IN The 50 MHz IF input This is at a 0 to 80 dBm level This is a 50 BNC female connector GND 15 J2 IF Output The 50 MHz output This is a 50 BNC output at 35 10 dB level The gain is automatically...

Страница 6: ...to Gain The 2097 07 operates over a 0 to 80 input In Automatic Gain AGC with S1 to AGC the gain is adjusted automatically to provide a constant 35 10 dBm output level over the entire 0 to 80 dBm input...

Страница 7: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect t...

Страница 8: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2010 Printed in USA 2097 07 Manual Re...