Cross Technologies 2016-57 Скачать руководство пользователя страница 1

Instruction Manual

                   

Model 2016-57  

Downconverter  

July 2020,   Rev.0   

MENU

EXECUTE

MODEL 2016

C

ROSS 

T

ECHNOLOGIES INC.

REMOTE

POWER

ALARM

DOWNCONVERTER

F = 5950.125      

G = +30.0     

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., 

but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. 

for purposes of operating the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment 
model number, equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

Содержание 2016-57

Страница 1: ...may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the eq...

Страница 2: ...pment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technol...

Страница 3: ...cy and gain settings appear on the LCD display Connectors are BNC female for IF output and the 10MHz reference input and output and Type N female for the RF input other connector configurations availa...

Страница 4: ...05 ns MHz linear 1 ns ripple Frequency Sense Non inverting Synthesizer Characteristics Frequency Accuracy 0 01 ppm internal reference or external reference input Frequency Step 125 kHz minimum 1 kHz...

Страница 5: ...kHz Frequency step Remote M C Interface Q RS485 422 W8 Ethernet with Web Browser WB W18 Ethernet with Web Browser WB SNMP W28 Ethernet with TCP IP Telnet Connector Options See TABLE 2 2 10 C to 40 C...

Страница 6: ...M C Cable Diagram Cross Technologies Frequency Converters Connector Rear panel DB 9 male J10 Pinouts RS 232C 422 485 Pinouts RS 232C 422 485 Pin Function 1 Rx 2 Rx RS 232C 3 Tx RS 232C 4 Tx 5 GND 6 Al...

Страница 7: ...hen RS 485 OPTION Q is selected TABLE 1 1 2016 57 Status Re equests Status Requests Command Syntax Description Command Status aaS1 Returns S1bbbbbbbccA where bbbbbbb Rx frequency in kHz 4 characters s...

Страница 8: ...ta depends on command stop byte PLEASE NOTE The two character aa 00 31 prefix in the table below should be used ONLY when RS 485 OPTION Q is selected Table 1 2 2016 57 Command ds Commands Command Synt...

Страница 9: ...igh by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assemblies The 2016 57 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 20...

Страница 10: ...ed 8 Not Used 9 Alarm Relay Normally Open Remote Serial Interface Interface DB 9 Female Protocol RS 232C 9600 baud rate no parity 8 data bits 1 start bit 1 stop bit 2 3 Front Panel Controls and Indica...

Страница 11: ...s 6 Be sure DS6 green DC Power is on and DS3 red Alarm is off Figure 2 3 7 AC Fuse The fuse is a 5 mm X 20 mm 2 amp slow blow Type T and is inserted in the far slot in the drawer below the AC input as...

Страница 12: ...85 address option Q Save Menu When R is selected in any above menu or at the end of the menu options Alarm indications appear on the LEDs see figure 2 3 All program changes must start with the operati...

Страница 13: ...ay desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switch 2 Hori...

Страница 14: ...g the downconverter frequency F 5950 125 R Pressing the Up Down switch down will toggle the display to F 5850 125 R By using the horizontal rocker switch the cursor can be moved left or right F 5850 1...

Страница 15: ...cursor location G 40 R By using the horizontal rocker switch the cursor can be moved left or right Pressing the Up Down switch will toggle the display digit selected until you have the desired gain G...

Страница 16: ...F OFF SCROLL SCROLL PUSH BUTTON PUSH BUTTON Power Up Normal Display Menu 1 Frequency Menu 2 Gain 30 to 50 Menu 3 Set Unit to Remote Operation Menu 4 Select External 10 MHz Reference Menu 5 Set Remote...

Страница 17: ...erloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring App...

Страница 18: ...HNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2016 57 Manual Rev 0 Page 1...

Отзывы: