background image

Содержание CRP3160GQQA

Страница 1: ...O PERSONS COULD RESULT INSTALL ANTI TIP DEVICE PACKED WITH RANGE SEE INSTALLATION INSTRUCTIONS Note For appfiances installed in the state of Massachusetts see page 2 RANGE OVERALL 253 4 DIMENSIONS _ 30 1 8 47 3 4 Maximum 44 5 8 Door Open 29 7 8 Clearance Minimum if Equipped 2 with 11000 or 4_ greater BTU Burners FRONT SIDE VIEW VIEW t Minimum to 1_ 13 4_1 Cabinets on Maximum Depth 18 Either Side f...

Страница 2: ...er safe use of all appliances Never leave the oven door open when the range is unattended Stepping leaning or sitting on the doors or drawers of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to re...

Страница 3: ...stalled to the wall make sure that screws completely penetrate dry wall and are secured inwood or metal When fastening to the floor or wall be sure that screws do not penetrate electrical wiring or plumbing a b Locate the Bracket Using the Template Bracket may be located on either the left or right side of the range Use the information below to locate the bracket if template is not available Mark ...

Страница 4: ...uct the flow of combustion and ventilation air For proper operation the maximum inlet pressure to the regulator should be no more than 14 inches of water column pressure The inlet pressure to the regulator must be at least 1inch greater than regulator manifold pressure Examples If regulator has been set for LP Propane gas 10 inch manifold pressure inlet pressure must be at least 11 inches Leak tes...

Страница 5: ...ng Be sure the gas supply inlet pressure is at least one inch above specified range manifold pressure The gas supply pressure should never be over 14 water column When properly adjusted for LP Propane Gas the manifold pressure is 10 5 Read electrical connection details below and connect electricity to range Before servicing disconnect electrical supply at circuit breaker fuse or power cord Electri...

Страница 6: ...ked for leaks and range has been connected to electric power a To check for proper lighting push in and turn a surface burner knob counterclockwise to the LITE position You will hear the igniter sparking The surface burner should light when gas is available to the top burner Purge air from supply lines by leaving knob in the LITE position until burner ignites Each burner should light within four 4...

Страница 7: ...he igniter has reached a temperature sufficient to ignite gas the electrically controlled oven valve will open and flame will appear at the oven burner There is a time lapse from 30 to 60 seconds after the thermostat is turned ON before the flame appears at the oven burner When the oven reaches the dial setting the glowing igniter will go off The burner flame will go out in 20 to 30 seconds after ...

Страница 8: ...n ordering parts for or making inquires about your range always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your range Your serial plate also tells you the rating of the burners the type offuel and the pressure the range was adjusted for when it left the factory Care Cleaning and Maintenance Refer to the Use Care Manual for cleaning instructi...